Fault Codes and Troubleshooting Chart
LED
Code
Smart View
Fault Code
Fault
Category
Possible Cause
Fault Clearance
2
F12001
1
Handbrake is on when direction is
selected.
Disengage handbrake.
5
F15001*
5
F15002*
5
F15003*
5
F15004*
5
F15005
1
Isolation fault detected between
logic and power frame.
Check isolation between low
and high voltage circuits
5
F15006
1
No motor speed feedback from
motor.
Check encoder wiring and
speed measurement signal.
5
F15007
1
Tow mode has been activated.
Disable tow mode if not re-
quired.
5
F15008
1
Invalid steer sensor state
Check steer sensor wiring
5
F15009
1
Pulsed enable signal not present,
unable to enable bridge.
Check 1kHz pulsed enable
signal is received
5
F15010
1
Unable to complete power-on
checks to allow bridge to enable.
Check motor connected or
wait for motor to slow down.
5
F15011
1
MOSFET/IGBT s/c tests at power
up are being held off.
Check motor connected or
wait for motor to slow down.
5
F15012
1
Battery electrolyte Low Level de-
tected
Check battery electrolyte level
5
F15013
1
Battery electrolyte Low Level de-
tected and cut back.
Check battery electrolyte level
5
F15014*
1
6
F16001
1
Warning level throttle fault. Used
on Renault Twizy.
Check throttle wiring and
installation.
6
F16002
1
Throttle appears to be stuck. This
fault will clear if throttle starts to
work again.
Check throttle wiring and
installation.
6
F16003
1
Throttle appears to be stuck. This
fault will latch and can only be
cleared by repairing the throttle
and recycling power.
Check throttle wiring and
installation.
6
F16004
1
Contactor driver over current
Ensure contactor doesn’t
exceed maximum current and
check contact wiring
6
F16005
1
Contactor driver not working
Internal hardware fault.
6
F16006
1
Contactor driver over temperature. Ensure contactor doesn’t
exceed maximum current and
check contact wiring
6
F16007
1
Contactor driver unable to achieve
current target in current mode
Ensure contactor driver current
target is within range.
6
F16008
1
Contactor driver MOSFET short
circuit dete
Internal hardware fault.
6
F16009
1
Analog supply is >10% out of
range.
Содержание PC NXG Series