IMPORTANT SAFETY INSTRUCTIONS

To assure the safe operation of this machine, you must read and understand all warnings and instructions in this book.  If you
do not understand, ask your supervisor.

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

WARNING

:  To reduce the risk of fire, electric shock, or injury:

1.

You must be trained to operate this machine.  This machine is to be operated for its intended use only.

2.

Do not operate this machine unless it is completely assembled.

3.

Always use a three-wire electrical system connected to the electrical ground.  For maximum protection against electrical
shock, use a circuit that is protected by a ground fault circuit interrupter.  Consult your electrical contractor.

4.

To prevent electric shock, always remove the electrical plug from the electrical outlet before doing any repairs or mainte-
nance and when leaving the machine unattended.

5.

To prevent electric shock, keep the machine surface dry.  Do not subject to rain. Store the machine in a dry building area.
Clean the machine with a dry cloth only.

6.

Machines can cause an explosion when near flammable materials and vapors.  Do not use this machine with or near fuels,
grain dust, solvents, thinners, or other flammable materials.  Do not use flammables to clean this machine.

7.

A qualified or authorized person must do maintenance and repairs.

8.

To prevent damage to the power cord, do not move this machine over the power cord.  Always lift the power cord over the
machine.  Do not pull or carry cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners.
Keep cord away from heated surfaces.

9.

Do  not  use  with  damaged  cord  or  plug.    If  the  machine  is  not  working  as  it  should,  has  been  dropped,  damaged,  left
outdoors, or dropped into water, return it to a service center.

This machine must be grounded.  If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock.  This machine is equipped with a cord having an equip-
ment-grounding conductor and grounding plug.  The plug must be inserted
into an appropriate outlet that is properly installed and grounded in accor-
dance with all local codes and ordinances.

WARNING

 - Improper connection of the equipment-grounding conductor

can result in a risk of electric shock.  Check with a qualified electrician or
service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the machine - if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.

This machine is for use on a nominal 120-volt circuit, and has a grounded
plug that looks like the plug illustrated in figure A.  A temporary adapter that
looks like the adapter illustrated in figures B and C may be used to connect
this plug to a 2-pole receptacle as shown in figure B if a properly grounded
outlet is not available.  The temporary adapter should be used only until a
properly grounded outlet (figure A) can be installed by a qualified electri-
cian.  The green colored rigid ear, lug, or the like extending from the adapter
must be connected to a permanent ground such as a properly grounded outlet
box cover.  Whenever the adapter is used, it must be held in place by a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code

EXTENSION CORDS

Use only three-wire 12/3 or larger gauge approved extension cords that have
three-prong grounding type plugs and three-pole receptacles that accept the
appliance’s plug.  Replace or repair any damaged cords or plugs.

When servicing, refer to authorized person only.  Use only identical replace-
ment parts.

Grounding Instructions

NOTE:

  Do not use adapters shown in figures B & C in Canada

2

Содержание Sea Ray 170

Страница 1: ...ealed freight damage If such damage is discovered file a CONCEALED DAMAGE REPORT immediately with the delivering carrier The contents of this manual are based on the latest product information available at the time of publication Pacific reserves the right to make changes or improvements to its machines without notice FORYOURCONVENIENCE RECORDTHEMACHINE MODELANDSERIALNUMBER MODEL__________________...

Страница 2: ...service center This machine must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This machine is equipped with a cord having an equip ment grounding conductor and grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accor dance with al...

Страница 3: ...brush off with a firm jerk to the left Remove the brush or pad driver when the ma chine is not in use This will help prevent brush damage and reduce wobble problems OPERATION Plug the machine s power cable into a properly grounded outlet see Safety Instructions Next adjust the handle height to a comfortable position Pull out on the Watch Dog Safety Lock button and start the machine by depressing e...

Страница 4: ...PX and SEA RAY Model Polishers 4 Alternate Kick Lever Assembly 1 9 2 10 11 12 3 5 6 7 4 8 ...

Страница 5: ...RIPTION QTY 485001 Kick Lever Assembly Includes 1 483702 Lever Grip 1 2 485124 Foot Lever 1 3 486701 Pin 1 4 W520D Washer Flat 5 16 I D 1 5 486702 Cotter Pin 1 6 980644 Washer Special Hardened 1 7 488401 Stud Threaded 1 8 480805 R H Arm 1 9 482003 Handle Clamp 1 10 480804 L H Arm 1 11 980003 Washer Flat 3 8 I D 1 12 920641 Nut M10 ESNA 1 ITEM PART NO DESCRIPTION QTY 30 980018 Washer 10 Countersunk...

Страница 6: ...2375 J Cover Start Capacitor 502308 502375 502308 502375 K Start Capacitor 911278 470MFD 125V 911239 400 480MFD 115V 911278 470MFD 125V 911239 400 480MFD 115V L Bolt 960035 960035 M End Bell 502931 502931 N Stator Asm 115V 60C 503124 503130 O Bearing Motor Top 902038 902003 902038 902003 P Stationary Switch 911277 911251 911277 911251 Q Rotary Switch 911219 911289 R Rotor Assembly 500436 500428 50...

Страница 7: ...ACMOTORILLUSTRATION WHITE WHITE BLACK BLACK GREEN GREEN MOTOR HANDLE COM COM N O N O POWER SUPPLY HANDLE SWITCH SINGLE PHASE GROUNDED 115 VOLTS GROUND WIRINGDIAGRAM ...

Страница 8: ...ement of return parts including motors etc is subject to incoming inspection of those items To secure repair under this warranty the following procedure should be taken The inoperative machine or warranted parts must be delivered to the authorized dealer with shipping and delivery charges prepaid If unable to locate the Dealer you may contact Pacific at the address listed herein for the location o...

Отзывы: