manualshive.com logo in svg
background image

art. 1510

WARNING:
* always read the instruction before using power tools
* always wear safety googles
* wear hearing protection

OPERATING INSTRUCTION

1. Warning

1.1 Air pressure

The air pressure must be restricted at or less than maximum presure 90

psi (6.2 bar), do not exceed it.

1.2 Air line

Use an air hose between the compressor and the tool. The corresponding

hose internal diameter is recommended in the attached table in the data

sheet. Compressed air is cooled and its water content separated as soon as

the air leaves the compressor. However some of the water is condensed in

the piping, and can enter the tool mechanism and cause damage. An air filter

and on oiler should be installed between the compressor and the tool. Use a

recommended compressor in the date sheet or larger for each tool.

Code

Air inlet

Pad ø thread

Stroke

Free speed

Inner - Hose

Max. Air pressure

Air consumption Vibration (m/s2) Weight

617733

1/4"

150 - 5/16"

2,5 mm

10000 RPM

8 mm

6,2 bar

368 l/min

<2,5

1186 g

617713

1/4"

150 - 5/16"

5 mm

10000 RPM

8 mm

6,2 bar

368 l/min

<2,5

1186 g

1.3 Air hose
Clean the hose with a blast of compressed air before connecting

the hose to air tool. This will prevent both moisture and dust within

the hose from entering the tool an causing possible rust or

malfunction. To compensate for unusually long hose (over 25ft)

the line pressure should be increased accordingly.

1.4 Approved eye protection, mask, hearing protection and gloves

shall be worn when operate this tools.

1.5 The working place shall be ventilated.
1.6 Release the on-off device in case of air supply failure.
1.7 Release the start and stop switch in case of a failure of energy

supply.
1.8 Use only a lubricant recommended by the manufacturer.

Pneumatic sander