4.1.1 OVERVIEW (continued)
The SETUP MODE is used to make changes in system configuration. Examples are:
Copy and Delete Programs
Copy, Edit, and Create Waveforms
Set Min. and Max. Voltage Limits
Set Min. and Max. Frequency Limits
Engage and Disengage CSC (Continuous Self Calibration)
Set the Metering Sense Point
– Internal or External
Set Slew rates
Set Transition Time
Set Transformer Ratio
Enable keyboard lockout
Set initial power on output voltage
Monitor UPC and Power Source status
View Firmware Version
Enable Calibration Mode for Metering
Adjust LCD View Angle and Backlight Intensity
Set GPIB Device Address or Serial Interface Parameters
Erase Memory
Set Amps-to-Volts Current Metering Ratio
Define Current Transformer Location
Set Output Range - for power sources that support it
Define the Number of Power Source Amplifiers
Synthesize Waveforms from Harmonic values (Option)
Enable, Set, and Calibrate Programmable output impedance (Option)
Enable Current Protection
SELECTING OPERATING MODES
On first turn-on, the system will operate using a set of default parameters stored in memory. The display will
be the V/I METER display. This is the default - and most frequently used - display. It shows all basic
operating parameters, and in the lower left portion shows the operating mode. All operating modes can be
accessed from the V/I METER display. If the V/I METER display is not active, pressing
CLEAR
a few times
will always return to the V/I METER display.
MANUAL OPERATION (
) - is available by pressing
Va, Vb, Vc
or
F
for voltage or frequency adjustments.
An LED will light above each pressed key to indicate an active selection. The selected parameter
can then be changed by typing a new value and pressing
EXECUTE
or holding one of the SLEW
keys (
︿
or
﹀
).
PROGRAM OPERATION (
) -requires pressing
PROGRAM,
selecting a program number (1-99) and
pressing
ENTER
to display the values stored in that program. Pressing
EXECUTE
will then cause
the UPC to use those values. If a transient has been stored in the active program, pressing
TRANS
will activate the transient.
PROGRAM EDIT (
– is accessed by pressing
PROGRAM,
select a program number (1-99) and press
ENTER
to display the stored program values. Press
EDIT
to allow changes to the values stored in
that program,
ENTER
to move the cursor through the screen, and
STORE
to save the values.
SETUP MODE (
) - Pressing the
fn
key presents the SETUP menu: copy or delete programs and
waveforms, erase memory, set meter sense points, toggle features on or off, set Programmable
Impedance (option), set range (if supported), transition time, frequency and voltage limits, LCD view
angle and backlight, perform metering calibration, view status for system information (e.g. firmware
version), GPIB device address or Serial interface parameters, transformer ratio, amps to volts ratio,
number of power amplifiers and current transformer location.
Содержание UPC-32
Страница 1: ...UPC 32 UPC 12 PROGRAMMABLE CONTROLLERS FIRMWARE V5 22 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE...
Страница 2: ......
Страница 15: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 32 Figure 1 3b UPC 32 Figure 1 3c UPC 12...
Страница 40: ...SECTION 4 OPERATION 30 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL...
Страница 127: ...NOTES 117 NOTES...
Страница 128: ...MODIFICATIONS 118 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made...