![Pacific Power Source UPC-32 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/pacific-power-source/upc-32/upc-32_operation-manual_3149812033.webp)
SECTION 3
INSTALLATION
23
3.4.3 CONFIGURE GPIB DEVICE ADDRESS
If the UPC is configured for serial port communication, see Section
Set the GPIB DEVICE ADDRESS as desired. The GPIB device address is set via the UPC STATUS
display screen. Default address is 1 (
NOTE:
IEEE-488 type cables with 90° "cable to connector" bends may interfere with other interface
connectors on the SCU and some power source model's rear panels. It is recommended that a straight
"cable to connector" IEEE-488 cable be used (e.g. NATIONAL INSTRUMENTS type X5) or a 90° adapter
may be used to provide needed clearance.
3.4.4 CONFIGURE MISCELLANEOUS SETTINGS
NOTE:
Configuration is preset at the factory if the UPC is packaged with a power source.
These settings are set by SWITCH S1 on the UPC INTERFACE PCB (
) and SWITCH S2 on
the UPC METERING PCB (
DIP-SWITCH CONFIGURATION SETTINGS
PCB
FIG.
Switch
Position
Description
INTERFACE 3.4.4
S1-1
ON
OFF
Current transformer on primary side of XFMR
Current transformer on secondary side of XFMR
INTERFACE 3.4.4
S1-2
ON
OFF
1 PA installed (Overrides METERING S2-7)
See METERING SW2-7 below
INTERFACE 3.4.4
S1-5
ON
OFF
Serial Interface Installed
IEEE-488 Interface Installed
INTERFACE 3.4.4
S1-6
ON
OFF
Front Panel Installed (keyboard and display)
Front Panel NOT Installed.
(Allows maximum Remote Interface performance)
INTERFACE 3.4.4
S1-7
ON
OFF
Metering PCB Installed
Metering PCB NOT Installed (for Enhanced Transient
& Remote Interface performance)
OFF position ignored if CSC is enabled
INTERFACE 3.4.4
S1-8
ON
OFF
Ф
B and
Ф
C Oscillators Installed (for 3
Ф
operation.)
Ф
B and
Ф
C Oscillators NOT Installed
METERING
3.4.1
S2-7
ON
OFF
2 power amplifiers installed
3 power amplifiers installed
Содержание UPC-32
Страница 1: ...UPC 32 UPC 12 PROGRAMMABLE CONTROLLERS FIRMWARE V5 22 AND LATER OPERATION MANUAL PACIFIC POWER SOURCE...
Страница 2: ......
Страница 15: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 32 Figure 1 3b UPC 32 Figure 1 3c UPC 12...
Страница 40: ...SECTION 4 OPERATION 30 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL...
Страница 127: ...NOTES 117 NOTES...
Страница 128: ...MODIFICATIONS 118 MODIFICATIONS MODIFICATIONS This section is reserved for any modifications that may be made...