Fireplace Installation into the Chase
The Fireplace must be installed into the Chase and vented as per the instructions in this
Instruction Manual.
Use
the following instructions to install the Craftsman Front mounting brackets and the Non-Combustible wall
board.
Mounting the Side Brackets
1. Drill out the top rivet and through
into the firebox front flange, using
a 7/32” drill bit.
2. Align the side bracket over
the two remaining rivet heads,
centering the holes.
3. Install one of the 1/4-20 thread
cutting screws through the large
hole in the bracket and into
the firebox front flange. Do not
tighten completely.
4. Using (5) #8 self-drilling screws,
fasten the Side Bracket to the
fireplace front using the holes
provided in the bracket.
5. Gently tighten all screws
6. Repeat the process on the other
side.
Removing the Upper and Lower
Grill assemblies:
• Remove the Upper and Lower
Louver Assemblies by remov-
ing the mounting screws located
on both sides, inside the upper
and lower grills using a 5/16” nut
driver ().
• Remove both grills. They will not
be reused.
A
B
Mounting Screws
STEEL STUDS PROVIDED WITH UNIT
MUST BE USED - SEE INSTRUCTION MANUAL
Figure 40: FP30.Body B Arch Surround.
4
2
1, 3
Figure 41: FP30 Craftsman side bracket screws.
37
100004186_040523-48
FP30 LE