Dimensions
Crate Removal
1. Carefully remove wood top and supports.
2. Remove the screws securing the fireplace to the pallet(4).
3. Remove from pallet bottom.
Fireplace Clearances and Chimney Restrictions
Distance
Distance of combustible material from the side or back standoffs and framing kit.
0” (0,0 mm)
Minimum distance from the adjacent side wall to center line of fireplace.
41 1/2” (1.054m)
Minimum distance from the adjacent side wall to the side of the fireplace door.
30” (760mm)
Ceiling clearance - both inside the chase and in the room: from the base of the fireplace
to the ceiling.
84" (2.13 m)
Minimum chimney height: - from the base of the Fireplace to below the chimney rain cap.
15’ (4.57 m)
Recommended maximum chimney height (at sea level) from top of fireplace to rain cap.
35’ (10.7 m)
Maximum unsupported chimney height.
15’ (4.57 m)
Minimum depth of non-combustible ember protection: from the front of the fireplace.
18” (457 mm)
Minimum width of Ember protection (8"from the side of the door opening in U.S.A.)
Minimum width of Ember protection (8" from the side of the unit in Canada).
39"
58” (1.47 m)
FP30 &
FP30AR
47”
[1.19m]
34 7/8”
[886mm]
9 5/8”
[245mm]
30 3/4”
[781mm]
42”
[1.07m]
30 1/8”
[765mm]
13 1/4”
[337mm]
28 1/2”
[724mm]
24”
[610mm]
Required framing kit is not shown in this diagram
56”
[1.42m]
1”
[25mm]
Figure 8: FP30 & FP 30 Arch Dimensions
16
100004186_040523-48
FP30 LE