background image

8

Pipe Support Set

Pipe Spacer

4" Vent Connector

8" Vent Connector

Firestop

4" Flex Pipe - 5' or 10' long

8" Flex Pipe - 5' or 10' long

Horizontal Vent Terminal

Roof Vent Terminal

Support Sleeve

Storm Collar

Flashing

Wall / Roof Thimble

4 1/2" Pipe Clamp

Fig. # 9

SEE APPENDIX A FOR A DETAILED LIST OF VENT KIT COMPONENTS

f i r e - p a r t s . c o m

Содержание Estate A Series

Страница 1: ...upplier s instructions Ifyoucannotreachyourgassupplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY I...

Страница 2: ...STAT 17 BURNER INSTALLATION 18 BRICK PANELS INSTALLATION 18 LOG SET ASSEMBLY 19 GLOWING EMBERS 20 OPTIONAL BLOWER 21 FIRST FIRE 23 OPERATING 23 FLAME ADJUSTMENT 23 REPLACEMENT PARTS 24 APPENDIX A 26 L...

Страница 3: ...by a qualified service person Do not use this heater if any part has been under water Immediately call a qualified service technician to inspect the heater and to replace any part of the control syste...

Страница 4: ...Combustibles Side standoffs 0 in 0 mm Back standoffs 0 in 0 mm Top standoffs 0 in 0 mm Adjacent sidewall 6 in 152 mm Ceiling to appliance 35 1 2 in 902 mm Mantel to appliance 17 in 432 mm Maximum mant...

Страница 5: ...FRAMING DIMENSIONS Examples of Common Locations system is installed Heavier construction may be required for some installations consult local building codes for specific requirements Ensure framing di...

Страница 6: ...combination of 16 rise and 14 run For longer venting configurations the rise and run must be constrained to the boundaries of this chart CAUTION UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSE...

Страница 7: ...TING NOTE The vent must be a minimum 4 long and must not exceed a total length of 40 Any combination of rise and run may be used but must be constrained to the bounda ries of this chart Fig 8b VERTICA...

Страница 8: ...ector Firestop 4 Flex Pipe 5 or 10 long 8 Flex Pipe 5 or 10 long Horizontal Vent Terminal Roof Vent Terminal Support Sleeve Storm Collar Flashing Wall Roof Thimble 4 1 2 Pipe Clamp Fig 9 SEE APPENDIX...

Страница 9: ...Spacers may have to be closer if pipe is bent 90 1 Bend pipe spacer around the 4 inch inner pipe With ends of spacer overlapped bend locking tabs into place see Fig 11 2 Slip the 4 1 2 inch pipe clam...

Страница 10: ...ntervals see Fig 10 Spacers may have to be closer if pipe is bent 90 The vent system must be supported approximately every 3 feet Use pipe support straps provided with kit to maintain a 1 inch clearan...

Страница 11: ...dow minimum 12 inches 30 cm recommended to prevent condensation on window D vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the cen...

Страница 12: ...Extend the 8 inch outer flex pipe through the roof opening Slip the flex pipe a minimum of 1 1 2 inches over the support sleeve Secure pipe to the sleeve with screws provided Seal the joint and screw...

Страница 13: ...m of 1 1 2 inches over the inner collar of the roof vent terminal Secure to the collar with screws provided Seal the joint and screw heads using the high temperature sealant provided 8 Lower the roof...

Страница 14: ...nt or your nearest Pacific Energy Authorized Dealer Before installing the Dura Vent system the installer should read the instructions that accompany this appliance to insure proper installa tion requi...

Страница 15: ...system to the Estate Fireplace flue outlet an Estate Pipe Adaptor is required A minimum 6 vertical length must be installed before the first 90 elbow With this minimum vertical rise a maximum horizon...

Страница 16: ...Snorkel Termination to the Estate flexible vent an Estate Snorkel Adaptor ESTD SNADPT is required 1 Attach the Estate Snorkel Adaptor to the Snorkel Terminal 2 Extend both the 8 inch outer and the 4...

Страница 17: ...gas supply connected to the appliance Correct gas pressure requirement Natural Gas Propane Min Pressure 5 0 wc 11 0 wc For purpose of input adjustment Max Pressure 10 5 wc 13 0 wc Manifold Pressure Ma...

Страница 18: ...t aside taking care not to damage them Remember the logs and panels are extremely fragile 4 The burner assembly has been packed separately to avoid damage during shipping Remove the entire assembly fr...

Страница 19: ...ated on the andirons with charred section facing forward 3 The top left log bridges across the front and rear log The log should be properly seated on the pin in the front log and nested in the left r...

Страница 20: ...ly over the front flame ports with remainder spread around the burner area This will produce the best results Note Only use embers supplied with this appliance Use of any other materials or incorrectl...

Страница 21: ...If the burner is already installed open bottom louver and install through opening 1 Tilt the blower on its side and slide it past the left side of the gas valve Position the blower onto the studs loca...

Страница 22: ...Off and call your service technician or gas supplier 9 Turn gas control knob counter clockwise to On position 10 Turn HI LO burner control knob to desired setting 11 Close bottom grill and turn on the...

Страница 23: ...LO burner control knob to a desired setting As heat is required the fieplace will turn on or off automatically Extend Shutdown To shutdown the appliance including the pilot partially depress and turn...

Страница 24: ...PTION PART NO 1 MAIN BODY MP1700 0 2 BURNER ASSEMBLY ESTD NAT PRO 3 PANEL RIGHT OR LEFT SIDE 5098 54 4 PANEL BACK 5098 53 5 EMBER BASE 5098 4 6 REPLACEMENT GLASS 5034 3 7 WINDOW GASKET KIT ESTD 50671...

Страница 25: ...25 Fig 33 fire parts com...

Страница 26: ...ith the screws provided see Fig 1 2 Fasten bottom louver to the hinge brackets at the bottom of the appliance see Fig 2 Fig 1 This kit contains 1 Top Louver 1 Bottom Louver 6 8 x 1 2 sheet metal screw...

Страница 27: ...l this kit The Overlay kit may be installed before installing the top and bottom louvers 1 Fold down the bottom louver to access the retaining screw just below the glass 2 Using a flathead or a 2 Robe...

Страница 28: ...Fibre washers 1 Top Panel This kit contains Metallic Black or Polished Brass finish Porcelain Enamel finish or This Installation Guide covers the following kits Metallic Black ESTD FTMBK Porcelain Ena...

Страница 29: ...5 attaching the bottom trim bar and replace with trim bar supplied with kit see Fig 1 3 Slide the spring nuts supplied over the slotted holes in the outer frame see Fig 1 4 Position the left and righ...

Страница 30: ...p outer frame with 8 x 1 2 screws and fibre washers provided see Fig 1 Without optional Front Facing Trim Kit Position the mantel shield under the top outer frame of the Estate fireplace and fasten in...

Страница 31: ...e 1 4 1 2 Pipe Clamp Wall Termination Kit GASC WALKIT This vent kit is for use with model The ESTATE and PACIFIC ENCORE series A fireplace only Please refer to the Installation Instructions provided w...

Страница 32: ...nt 1 Mastic 1 Roof Vent Terminal 1 Wall Roof Thimble 1 Support Sleeve 1 Storm Collar 2 Roof Brackets Roof Termination Kit ESTD ROTKIT This vent kit is for use with model The ESTATE and PACIFIC ENCORE...

Страница 33: ...ireplace only Please refer to the Installation Instructions provided with the appliance for proper venting installation This box contains 3 Pipe Spacer 2 8 x 1 2 sheet metal screws 8 10 x 5 8 teks scr...

Страница 34: ...nly Please refer to the Installation Instructions provided with the appliance for proper venting installation This box contains 10 4 Flex Vent 10 8 Flex Vent 1 4 Vent Connector 1 8 Vent Connector 1 Fi...

Страница 35: ...MANUFACTURED MOBILE HOME FABRIQUEZ MOBILE MAISON May be installed in Manufactured Homes after the first sale See Instructions Pouvez tre install s dans a Fabriqu des Maisons apr s le premi re vente V...

Страница 36: ...36 Pacific Energy Fireplace Products Ltd PO Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site www pacificenergy bc ca Printed in Canada fire parts com...

Отзывы: