PH3 EL AUTOMATIC ACTUATION
L6319
10
N O R M A L VA LV E O P E R AT I O N
Automatic function or manual override can be used to shut down the engine during an over speed event
CAUTION: Do not attempt to start the engine after an over speed condition occurs until the cause is
understood and shared with the necessary safety parties.
NOTE: Please reference your organizations specific operation procedures and ensure they are in line with
the PowerHalt operating instructions and requirements. If there is a discrepancy always follow your site
requirements first.
11
VA LV E M A I N T E N A N C E R E Q U I R E M E N T S
As the PH3 is a maintenance free and self-checking valve, it does not require any specific operator
involvement. The PH3 performs an anti-foul cycle every time the engine comes to a stop after a period of
running. However if the unit is stored for extended periods, or run for extended periods without pause, it
is imperative that the engine run and shut down monthly so that the PH3 valve can perform its anti-foul
cycle.
12
M O N T H LY I N S P E C T I O N R E Q U I R E M E N T S
• Inspect all fasteners and clamps to ensure proper torque.
• Inspect all hoses and pipes for signs of wear or vibration related issues.
• Inspect all wiring connections and routing to ensure correct strapping.
• Inspect the PowerGuard controller with unit running to ensure the green
led
light is flashing
every 5 seconds.