PH3 EL AUTOMATIC ACTUATION

L6319

8

 

P O W E R G U A R D   T E S T   P R O C E E D U R E 

TO ENTER TEST MODE:

  With the engine running, hold the reset and test buttons together for 5 seconds until both

 

led

 lights start 

flashing, and then release both buttons

  Press and release the TEST button to enter test mode, where the trip point will be reduced to a lower limit 

based on number of presses from prior set-up procedure. 

  

1.

 90% of original 

rpm

, or 82% of trip point

  

2.

 90% of original 

rpm

, or 75% of trip point

  

3.

 90% of original 

rpm

, or 69% of trip point

  

4.

 100% of original 

rpm

, or 50% of trip point

  The controller will wait for 60 seconds before reverting back if trip point is not reached.
  If the RPM trip point is reached, the valve will close and the red 

led

 will illuminate until 0 

rpm

 is detected 

and either 30 seconds elapses or the TEST button is pressed

  Next, the valve will automatically re-open and the red 

led

 will extinguish

9

 

P O S T   I N S TA L L AT I O N   T E S T I N G

  Once the installation is complete, ensuring all steps, schematics and recommendations have been 

followed, it is now time to test your system

  

1.

 Press the red TRIP button and confirm the red 

led

 is illuminated. Wait 30 seconds for the valve to  

    auto reset

  

2.

 Start the engine

  

3.

 Press the red TRIP button and ensure:

        •  The engine stops within a few seconds
        •  Hose collapse is not severe
        •  No excessive leaks are present in the system
 

NOTE: if the engine does not fully shut down check all intake piping and hoses for leaks between 

the valve and intake system. If the system is sealed and the valve still fails to shut down the engine 

consult your Pacbrake service representative for support

  

4.

 Once the engine stops wait 30 seconds until the valve automatically re-opens and the red

 

led

  

    turns off

  

5.

 Utilize the test mode as per PowerGuard Test Procedure to ensure that the automatic overspeed is  

    functioning properly

Содержание Powerhalt PH3

Страница 1: ...ENCY SHUT OFF V AL VE AIR INTAKE EMERGENCY SHUT OFF V AL VE www powerhalt com PH3AIR INTAKE EMERGENCYSHUT OFFVALVE AUTO ELECTRIC WITH AUTO RESET For LTW20 20KW BV 4LEZ Engines WITH POWERGUARD SMART OV...

Страница 2: ...pe quality and integrity from the shut off valve to the intake manifold should be confirmed NOTE Failure to ensure this may result in hose collapse during valve activation and possible system leaks pr...

Страница 3: ...n this kit before you start the installation Drill 1 4 Drill Bit Ratchet with 7 16 1 2 Sockets a 14 extension is ideal Utility Knife 11 8 Metal Unibit 1 8 Hex Allen Key REQUIRED TOOLS KIT CONTENTS A B...

Страница 4: ...d Install the 2 2 silicone hoses provided in your kit and 2 2 pretension clamps onto the PH3 2 Shut off valve Adjust clamps and tighten to 70 80 in lbs 7 9 9 N m Insert 2 stock clamps onto the valve a...

Страница 5: ...2 8 N m CAUTION Do not over torque nuts 4 M A G N E T I C P I C K U P I N S TA L L AT I O N On your LTW20 BV 4LEZ light tower locate the factory installed magnetic pick connector in your control pane...

Страница 6: ...lve free of debris and corrosion This results in an extended valve life If the valve is tripped manually or automatically the valve will close and the red led will illuminate When 0 rpm is detected an...

Страница 7: ...controller error Contact Pacbrake support at 800 663 0096 7 P O W E R G U A R D S E T U P T E S T P R O C E D U R E TO SETUP RPM With the engine running hold the reset and test buttons together for 5...

Страница 8: ...elapses or the TEST button is pressed Next the valve will automatically re open and the red led will extinguish 9 P O S T I N S TA L L AT I O N T E S T I N G Once the installation is complete ensurin...

Страница 9: ...I N T E N A N C E R E Q U I R E M E N T S As the PH3 is a maintenance free and self checking valve it does not require any specific operator involvement The PH3 performs an anti foul cycle every time...

Страница 10: ...HEADQUARTERS R D CENTER 19594 96TH AVENUE SURREY BRITISH COLUMBIA WIRING SCHEMATIC PIN 2 RED PIN 3 RED PIN 15 RED POWERGUARD PIN 1 BLACK PIN 13 BLACK PIN 14 BLACK PIN 24 WHITE PIN 24 BROWN PIN 23 BLUE...

Отзывы: