PowerHalt is a registered trademark of Pacbrake Co.
3
PH2 - AUTO / MANUAL / ELECTRIC WITH PULL CABLE(S)
L6372
L6372_REV6.17.04.2018
ECN 1-1859
Thank you for your purchase of a PowerHalt Air Intake Emergency Shut-Off Valve by Pacbrake.
Please read the entire manual before beginning to ensure you can complete the installation once started.
Should you have any issues during the installation, please call technical support at 800.663.0096.
2A
CORRECT
INCORRECT
2B
1
VALVE INSTALLATION
Disconnect the battery.
Remove the engine panels or covers to gain access to
the intake hose location where the shut-off valve will be
installed.
2
Remove the stock clamps and hoses from the air cleaner
and intake manifold.
Take the provided silicone hoses, install them on the air
cleaner outlet and intake manifold.
NOTE: Ensure the hoses are fully sealed onto the valve
(see photo 2B).
3
Install the provided pre-tension clamps on the hoses and
leave them loose.
4
Install the PH2 valve into the hoses openings. After the
installation, rotate the valve accordingly; ensuring the pull
cable armature is in the upright position.
5
Torque all 4 clamps to 70 - 80 in-lbs (7.9 - 9 N•m).