VB 40/1000 Zero 

Flow sensitive unloader valve

                                                      PATENTED 

Pressure regulating valve unloader type with zero setting on delivery line: at 
gun closure the water flow is bypassed at low pressure maintaining also the 
delivery line in low pressure. 
 

Technical manual

: MPA0004EN 

 
 

 

                                                                                                                                                             

DN 10 

 

 

 

 

TECHNICAL SPECIFICATIONS 

Construction material

: Sst.

 

 

PART 

NUMBER 

 
 
 
 

MINIMUM 

FLOW 

 

 

MAXIMUM  

FLOW 

 
 

WORK 

PRESSURE 

 

ADJUSTABLE 

MINIMUM 

PRESSURE 

 

MAX 

TEMPERATURE 

(1)

 

 

WEIGHT 

 

 

IN 

OUT 

 
 
 
 

 

BYPASS 

l /min 

USG 

l / min 

USG 

bar  

MPa 

bar  

MPa 

°C 

°F 

oz. 

60.2900.00 

 9    

 2.4 

40     

10.5 

1000  

100 

500 

50 

95    

203 

4650 

164 

G 3/8” F 

G 3/8” F 

60.2900.12 

2.4 

15 

4.0 

1000 

100 

500 

50 

95 

203 

4650 

164 

G 3/8” F 

G 3/8

” M 

60.2900.20 

2.4 

25 

6.5 

1000 

100 

500 

50 

95 

203 

4650 

164 

3/8” F 

G 3/8

” M 

60.2900.30 

2.4 

35 

9.2 

1000 

100 

500 

50 

95 

203 

4650 

164 

G 3/8” F 

G 3/8

” M 

 
 

1) 

The valve has been designed for a continuous use at a water temperature of 

60°C (140°F)

 

It can work for short periods at a maximum temperature of 

95°C (203°F)

.

 

 
 
 

 

60.2900.XX

   VB 40/1000 Zero                                   G 3/8

”  FF  

 

 

o

 

Near total zero setting of the pressure in the delivery line at gun closure. 

        Advantages: 

 

Increased safety for the operator. 

 

Delivery hose easy to control when gun is closed. 

 

Less force needed to reopen the gun. 

 
 

o

 

At gun reopening, work pressure is reached gradually. 
Advantages: 

 

Operators work less heavy. 

 

Easy starting if thermal engine is used. 

 

 

o

 

Reduced pressure loss and hardly dependent on flow rate. 

o

 

Great reliability. 

o

 

Easy maintenance. 

o

 

Three versions with different working pressure but one sole range of flow 
rate from 9 up to 40 l/min. 
 

 

 

 

Содержание VB 40/1000 Zero

Страница 1: ... OUT BYPASS l min USG l min USG bar MPa bar MPa C F g oz 60 2900 00 9 2 4 40 10 5 1000 100 500 50 95 203 4650 164 G 3 8 F G 3 8 F 60 2900 12 9 2 4 15 4 0 1000 100 500 50 95 203 4650 164 G 3 8 F G 3 8 M 60 2900 20 9 2 4 25 6 5 1000 100 500 50 95 203 4650 164 G 3 8 F G 3 8 M 60 2900 30 9 2 4 35 9 2 1000 100 500 50 95 203 4650 164 G 3 8 F G 3 8 M 1 The valve has been designed for a continuous use at ...

Страница 2: ...s The adjustment is made by altering by means of a piston the position of a sphere which closes partially the bypass opening The valve is sensitive to water flow At gun opening the water flows through the valve which maintains the system in pressure At gun closure the interruption of the flow provokes the complete aperture of the bypass which allows to discharge the flow at low pressure At gun clo...

Страница 3: ...advisable to fit in the feed line of the machine a low pressure pump that guarantees a feed pressure of the high pressure pump of 3 5 bar See paragraph EXAMPLES OF INSTALLATION Picture 4 It is advisable that the tank be provided with deflectors to reduce eventual turbulence and air bubbles generated by the intake of the bypass flow which could be harmful for the pump In the case of direct pump rec...

Страница 4: ...Ultimo aggiornamento 15 11 19 4 EXAMPLES OF INSTALLATION ...

Страница 5: ...utter blocked pos 33 on exploded view Clean and eliminate obstruction Valve does not reach maximum pressure Worn nozzle Replace Presence of matter between seat and shutter Clean the seat Seat damaged or worn Replace Valve does not go into pressure O rings of Sst piston pos 8 9 10 e 13 14 15 of the exploded view ruined Replace MAINTENANCE STANDARD every 400 working hours check and lubricate the sea...

Страница 6: ...p ring 23 2x26x1 2mm 1 10 21 60 2904 51R Lower plug sst 1 3 22 60 2902 21R Sst valve piston VB40 1000 Zero 1 5 23 10 4161 00R Back up ring 18 mm 1 3 24 10 4013 09R Back up ring 13 1x18x1 2 mm 1 10 25 10 4060 09R Back up ring 20x22 8x1 2 mm 1 10 26 10 3072 95R O ring 1 78x20 35 mm Hnbr 85 1 10 27 60 2905 55R Housing VB40 1000 Zero 3 8 Bsp F sst 1 3 28 10 4008 93R Back up ring 9 3x14 2 x2 2 mm 1 5 2...