This manual provides the information needed for proper use and maintenance of this air conditioner. 

Basic preventative care can help extend the life of this unit. The “Troubleshooting” section in this 

manual contains a chart with solutions to the most common problems. Referring to this section may 

save time and prevent the need for a service call in the even of a problem.

 OPERATING CONDITIONS

The air conditioner must be operated within the temperature range indicated below: 

MODE

ROOM TEMPERATURE

COOL

64°F – 90°F

 ENERGY SAVING TIPS

•  Use the unit in the recommended room size.

•  Locate the unit where furniture cannot obstruct the air flow.

•  Keep blinds/curtains closed during the sunniest part of the day (cooling mode).

•  Keep doors and windows closed to keep cool air in and warm air out (cooling mode) or keep warm 

air in and cool air out (heating mode for units with heating function).

NOTE:

 All the illustrations in this manual are for explanation purposes only. Unit purchased may be 

slightly different.

The design and specifications are subject to change without prior notice for product improvement. 

Contact Consumer Services at 844-4PA-AIRE (844-472-2473) for details.

CONTENTS

IMPORTANT SAFEGUARDS ..............................................................................1
LCDI POWER CORD & PLUG ............................................................................2
PARTS DIAGRAM ................................................................................................3
WINDOW KIT PARTS & INSTALLATION ..........................................................4
DESCRIPTION OF THE CONTROL PANEL ......................................................7 
OPERATING THE CONTROL PANEL ................................................................7
TIPS FOR BEST PERFORMANCE ......................................................................10
WATER DRAINAGE ............................................................................................10
REMOTE CONTROL ...........................................................................................12
MAINTENANCE ..................................................................................................15
UNIT SPECIFICATIONS ......................................................................................16
TROUBLESHOOTING .........................................................................................17

NOTE: 

Performance may be 

reduced outside of these 

operating temperatures.

Содержание 1PPEC8000

Страница 1: ...RTABLE AIR CONDITIONER FOR MODELS 1PPEC8000 1PPEC10000 1PPEC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANU...

Страница 2: ...________________________ Purchase Date ________________________________________ Store Purchased _______________________________________ Installation Date ______________________________________ Install...

Страница 3: ...ed during the sunniest part of the day cooling mode Keep doors and windows closed to keep cool air in and warm air out cooling mode or keep warm air in and cool air out heating mode for units with hea...

Страница 4: ...f gas and the amount please refer to the relevant label on the unit itself Installation service maintenance and repair of this unit must be performed by a certified technician Product uninstallation a...

Страница 5: ...ning or performing maintenance Unit must be plugged into its own dedicated outlet Never unplug the unit by pulling on the power cord Do not install the unit in rooms containing gas oil or sulfur Do no...

Страница 6: ...est follow the steps below that correspond to the plug on your unit NOTE Your unit s power cord may differ from the one shown If test button is pressed and unit can still be turned on current leakage...

Страница 7: ...charge Opening 9 Condensation Drain Hole 10 Power Cord 10A Power Cord Wrap 11 Exhaust Hose 12 Window Kit Adapter 13 Exhaust Hose Connector 14 Remote Control 15 Caster Locks 16 Window Kit Screws 2x 17...

Страница 8: ...The window kit and exhaust hose do not need to be installed when the unit is used as a fan or in DRY mode NOTE The supplied window kit can be installed in sliding windows or double hung windows up to...

Страница 9: ...her 1 Assembly Panel Slide Panel B and C into Panel A and size to window width Win dows sizes vary When sizing the window width be sure that the window kit assembly is free from gaps and or air pocket...

Страница 10: ...ess 4 Attach the Window Kit Adapter to the Window Kit Attach the Window Kit Extension Adapter to the Window Kit Adapter if necessary Close the window tightly Your Portable Air Conditioner is ready to...

Страница 11: ...s of the unit but to fully utilize the unit s features you must use the remote control TURNING THE UNIT ON MODES Plug unit into the wall outlet Two lines appear on the display indicating that the unit...

Страница 12: ...comfort Maximum speed to achieve the target tempe rature as rapidly as possible Auto fan the unit automatically selects the most suitable fan speed in relation to the temperature set on the digital d...

Страница 13: ...ther to operate in COOL or FAN mode To properly set this mode Press the MODE button until the SMART symbol appears SLEEP FUNCTION This mode can only be set with the remote control Please refer to remo...

Страница 14: ...ace caster locks under the front wheels This air conditioner is equipped with MIST technology which means the water tank nearly never fills Hence water drainage will generally only be required at the...

Страница 15: ...oner by pressing the ON OFF button Ensure that the unit is in COOL or DRY mode The compressor will start approximately 3 minutes after the unit is switched on CONTINUOUS DRAINAGE SEE FIG B BELOW Thoug...

Страница 16: ...emote control and the receiver The remote control must be handled with extreme care Do not drop it or expose it to direct sunlight or sources of heat For best operation do not mix old and new batterie...

Страница 17: ...ed by pressing the FAN button until the required speed is selected AUTO HIGH MED LOW NOTE In COOL mode the unit automatically removes excess moisture from the air DRY MODE Keep the windows and doors c...

Страница 18: ...the SWING button to activate this function Press the SWING button again to deactivate this function SETTING THE TIMER The timer can be used to delay the unit s start or stop time to avoid wasting elec...

Страница 19: ...CE CLEANING Before cleaning or performing maintenance turn the unit OFF by pressing the ON OFF button on the control panel or ON OFF button on the remote control Wait for a few minutes then unplug fro...

Страница 20: ...t speed setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the temperature of the operating environment is higher than the...

Страница 21: ...lter is dirty Clean filters as described in this manual There are heat sources in the room oven hairdryer etc Eliminate the heat sources The air exhaust hose is detached from the unit Fit the exhaust...

Страница 22: ......

Страница 23: ......

Страница 24: ...y Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PP...

Отзывы: