TIMER ON FUNCTION
1. With the unit ON, set operating mode, temperature and fan speed
before setting TIMER ON function.
2. Press ON/OFF button to switch into STANDBY.
3. Press the TIMER button twice. The is displayed above the
TIMER ON to indicate that it is active.
4. Set the time you want the unit to switch off using the and
buttons (from 30 minutes to 24 hours).
• During the first 10 hours you can select 30 minute intervals up to 9.5 hours; After 10 hours, only 1
hour intervals can be selected.
5. Press the TIMER button again to confirm the setting. The TIMER icon on the control panel will
be activated.
• At the end of the set time, the unit switches ON automatically.
• To cancel the TIMER setting, press the TIMER button again at any point during the set time.
ON
OFF
MAINTENANCE
CLEANING
Before cleaning or performing maintenance, turn the unit OFF by pressing the ON/OFF button on
the control panel or ON/OFF button on the remote control. Wait for a few minutes, then unplug
from the main wall outlet.
CLEANING THE CABINET
You should clean the unit with a slightly damp cloth, then dry with a dry cloth.
•
NEVER
wash the air conditioner with water. It could be dangerous and damage the unit.
•
NEVER
use petrol, alcohol, or solvents to clean the unit.
•
NEVER
spray insecticide liquid or similar substances on the unit.
CLEANING THE AIR FILTERS
To keep your air conditioner working efficiently, you should
clean the filters every week.
The filters are housed behind the upper and lower intake
grilles. (See figure on right.)
Use a vacuum cleaner to remove dust accumulation from the
filters. If they are very dirty, immerse them in warm water and
rinse them a number of times. After washing, let the filters dry
completely, then place them securely back into the unit.