P3 V3 Analog Inputs
3 Analog Inputs
Yellow
Purple
Black - Dedicated port for P3 analog boost sensor
Brown
- Analog input 1 (the output wire of any 0-5 volt linear output sensor can be connected
here)
Blue
- Analog input 2 (the output wire of any 0-5 volt linear output sensor can be connected
here)
Setting Up an Analog Input using pre-configured scaling
*directions shown for analog 1, directions are same for analog 2
1- Enter the configuration menu of your gauge by holding both buttons until you see "ConF"
2- Tap the right button until you see "A1.n" for Analog 1(
brown wire
)
3- Tap the left button to change it from "A1.n" to "A1.Y"
4- Tap the right button to select a pre-configured scaling setup ("EC"=ethanol content from
ESVA / "Ft"=fuel temp from ESVA / "LC"=Air/Fuel ratio from LC-2 wideband kit/ "PS"=Pressure
reading from P3 Pressure Sensor)
5- Hold the right button until the screen turns off to save/exit the menu
Setting Up an Analog Input using manual sensor scaling
*directions shown for analog 1, directions are same for analog 2
1- Enter the configuration menu of your gauge by holding both buttons until you see "ConF"
2- Tap the right button until you see "A1.n" for Analog 1(brown wire)
3- Tap the left button to change it from "A1.n" to "A1.Y"
4- Tap the right button until you see "A1.dp" (this is the decimal point setting)
5- Wait for the screen to cycle to "9999" and then tap the left button to place the decimal point
6- Tap the right button to move on to "A1.Lo" (this is the minimum sensor value)
7- Tap/hold the left button to set your minimum sensor value
9- Tap the right button to move on to "A1.HI" (this is the maximum sensor value)