background image

8

- mode

[Pr 0]

– continuous work.

- mode

[Pr 1]

- pomp work depends on additional thermostat work mode. In

[Fc 0] mode central heating pump is turned on when room temperature is too low

(additional thermostat connection shorted or room temperature lower than temperature

set with additional thermostat knob). The pump is turned off when room temperature

reaches desired value. In [Fc 1] mode central heating pump is turned on when

measured exhaust gas temperature is higher than temperature set with additional

thermostat knob. The pump is turned off when exhaust gas temperature drops below

the set temperature.

- mode

[Pr 2]

– in this mode the central heating pump will turn on only when the

controller is in WORK mode.

Central heating pump pause time [Pc--]

– when boiler temperature exceeds

temperature set with

[P 65]

parameter and pump work mode doesn't allow turning the

pump off (e.g. thermostat contacts open) the pump can be periodically turned on for 30

seconds in order to move water in heating installation. This parameter sets pause time

in minutes between pump work periods. Setting this parameter to „--” disables this

function.

Central heating pump turn off delay [Pd 2]

– central heating pump stopping too

early can cause temperature rise in the boiler and cause its overheating. This

parameter allows setting central heating pump turn off delay. Setting this parameter to

„--” means that the pump will be stopping without delay.

6.3. Boiler work temperature setting.

Minimal boiler temperature [L 65]

- minimal temperature, which you can set with the

boiler thermostat knob.

Maximum boiler temperature [H 90]

- maximum temperature, which you can set with

the boiler thermostat knob.

Boiler temperature hysteresis [h 5]

- this parameter defines what value should

temperature of water in the boiler decrease by, below temperature set with the

thermostat knob, to turn the pressure fan on.

6.4. Boiler overheating protection.

Boiler overheating temperature [A105]

- value, exceeding which causes permanent

turn off of the pressure fan and launch of the circulating pump, to prevent boiler

overheating. Overheating mode is indicated by boiler overheating indicator and by

displaying error

[E 2]

on the display. It can be turned off by pressing STOP button, but

only when temperature decreases below boiler overheating temperature. Pressure fan

turning off occurs also in case of damage of the boiler temperature sensor, which is

displayed on the display by error

[E 1]

.

Содержание RK-2001AT2

Страница 1: ...OPERATION MANUAL SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER RK 2001AT2 Version AC22...

Страница 2: ...r starts in HEATING UP mode This mode turns off influence of exhaust gas thermostat on the fan and central heating pump HEATING UP is active until exhaust gas temperature achieves temperature set with...

Страница 3: ...shows diagram of electrical connection of the device WARNING Before plugging the device to the power source check if it is proprerly grounded and if the screws of the connector are properly screwed CA...

Страница 4: ...on stops the fan for example allowing to add fuel to the boiler If the controller isn t in service mode the display shows water temperature of the boiler and the last sign on the display defines mode...

Страница 5: ...splays current measured room or exhaust gas temperature 6 Setting up the parameters service mode Holding OK button for more than 3 seconds causes change to service mode where you can view and change p...

Страница 6: ...ng pump turn off delay 1 99 1min 2 L 65 Minimum boiler temperature 60 65 1 C 65 H 90 Maximum boiler temperature 80 95 1 C 90 h 5 Boiler temperature hysteresis 1 10 1 C 5 A105 Boiler overheating temper...

Страница 7: ...meter value in range from 0 to 10 means time in minutes of the smooth fan speed increase from 40 to value of for smooth boiler start Fan work time n 5 time of turning the fan on for a while to remove...

Страница 8: ...ion Central heating pump turn off delay Pd 2 central heating pump stopping too early can cause temperature rise in the boiler and cause its overheating This parameter allows setting central heating pu...

Страница 9: ...described above When contacts are open the controller will keep minimum boiler temperature Attention When external thermostat is connected in place of room temperature sensor the temperature set with...

Страница 10: ...ing boiler start Fuel shortage testing time in work mode Fb30 time set with this parameter is used when testing fuel shortage after boiler has started Setting this parameter to disables fuel shortage...

Страница 11: ...are working correctly After detection of fault it stops the pressure fan turns on the circulating pump and shows proper error message on the display In case of failure please turn off the controller p...

Страница 12: ...urement range 9 109 C 1 C Boiler temperature adjustment range 30 90 C 1 C Programmable boiler overheating protection 90 99 C 1 C Hardware boiler overheating protection 95 C 1 C Circulating pump launch...

Страница 13: ...13 Picture 2 RK 2001AT2 connection scheme Picture 3 UM 1 module connection scheme...

Страница 14: ...controller work mode Pc Central heating pump pause time Pd 2 Central heating pump turn off delay L 65 Minimum boiler temperature H 90 Maximum boiler temperature h 5 Boiler temperature hysteresis A105...

Страница 15: ......

Страница 16: ...Producer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Отзывы: