36
MAN 9058167 EN V1
P. Lindberg A/S
Sdr. Ringvej 1
www.p-lindberg.dk
Tel.: +45 70 21 26 26
DK-6600 Vejen
e-mail: [email protected]
4.
Remove the connecting bolts between the pump and the frame.
Inlet valve
If you suspect that the inlet valve is clogged or stuck, take it out and clean or replace
it.
1.
Remove the suction hose from the
sprayer.
2.
Loosen the inlet valve and remove
it.
3.
Remove any dirt and dried paint
from the cavity and replace the ball
and spring. Tighten the inlet valve
to the pump again.
4.
Be extremely vigilant regarding the
direction of the tapered spring when reinstalling the ball and spring.
Note: Be careful not to lose the ball and spring
inside the inlet valve. They may fall out when
the inlet valve is removed. The pump cannot
prime without the ball and spring.