Elektronics

Batteri-/Energy monitor

Terminals 5, 7, 9 and 10 have battery monitors to prevent deep 

discharge which will damage the batteries (also frost protection). 

Terminal 10 is switched off at 19 V and others at 21 V. All terminals 

open  again when  charging commences and  the voltage exceeds 

23.5 V.
Terminal 10 also has an energy monitor = If P-LIGHT is inactive for 

270 hours, terminal 10 is closed and opens again when the parking 

lights come on again via P-LIGHT (pushbutton 1) or the truck. 

Built-in test program

P-LIGHT® comes equipped with its own test program for monitoring 

and fault tracing. In order for the test program to show all values, 

the truck’s lighting must be switched on.
To access the menu, press and hold pushbutton 1 on the P-LIGHT® 

box for approx. 8-10 seconds. You can release the button when the 

program starts. A rolling menu is then shown on the controller’s 

display. The program’s version number is displayed first, followed 

by the voltage (V), in the following order.
Code Terminal 

Benchmark

U4 Voltage on terminal 4 (Circuit 1 in) 

 

min 24V

U6 Voltage on terminal 6 (Circuit 2 in) 

 

min 24V

U8 Voltage on terminal 8   

             

0V

UC Voltage out from the

built-in charger/booster                     

approx. 28/20°C

U1 Voltage on terminal 1   

approx. 25V

(P-LIGHT® batteries)
A tripped MCB is indicated by the text “Err” alternating with “f x” 

where “x” is the MCB that has tripped.

Error code on P-LIGHT, C11 och CC1

If the error code “C11” or “CC1” appears on the display, it means 

that the batteries have been deeply discharged with low battery 

voltage as a result. This may be due to both a fault in the charger, 

but also a large output demand without the battery having had 

time to recharge sufficiently while driving the vehicle.
If the battery voltage drops below the programmed limit, terminal 

10  (AUX)  switches  off  and  then  indicates  “C11”  on  the  display. 

Restarting  requires  5  minutes  of  voltage  on  terminals  4  and  6 

(truck connected and lighting on). If the voltage in the batteries 

after this time exceeds the programmed limit, terminal 10 (AUX) 

is activated again. It is important that the batteries have time to 

receive a proper charge again after this.
If the voltage does not exceed 24 V after 5 minutes, terminal 10 

(AUX) remains off and “CC1” appears instead. This test is repeated 

each time voltage is connected to terminals 4 and 6 for at least 5 

minutes. If the “CC1” indication does not clear after a few attempts, 

the charger or batteries are probably damaged. In this case, contact 

the appropriate workshop for inspection and possible replacement 

of the controller/batteries.

Programmable switching

Press and hold pushbutton 2 (the top one) for at least 20 seconds.
A message will then appear on the display, do you want to change, 

repeat the procedure.
AUT ON = P-LIGHT® ALWAYS switches on outputs 5 and 7 when the 

truck is switched off or disconnected.
AUT OFF = P-LIGHT® NEVER switches on outputs 5 and 7 when the 

truck is switched off or disconnected (Factory setting on delivery).

Resettable circuit breaker funktion

If  any  of  the  MCBs  trip,  this  is  shown  on  the  display  (on  the 

controller)  by  an  alternating  message  of  “Err”  and  “F  x”,  where 

“x” is the tripped MCB-ID. If the truck is disconnected, the circuit 

breaker fault is only displayed for 30 seconds after pressing the 

button, to save the battery. However, if the vehicle is connected, 

the message is displayed continuously.
NOTE: If a MCB trips, the supply must be disconnected (for 15-60 

sec) in order for the MCB to reset. If the tripped circuit breaker has 

been caused by a short-circuit in a bulb, this must also be rectified.

Terminals 5, 7, 9 and 10 have built-in MCBs, max simultaneous 

output 270 W (11 A).
If,  for  some  reason  it  is  necessary  to  bypass  the  P-LIGHT® 

controller, the wires on terminals “4” and “5”, as well as “6” and 

“7”, must be connected together.

Fuse id

Func�on

1

Terminal 1 (Ba�ery)

5

Terminal (Out cct 1)

7

Terminal 7 (Out cct 2)

9

Terminal 9 (Out Op�on)

10

Terminal 10 (Out AUX)

C

Charger

Содержание Maxi

Страница 1: ...HyCover ngsg rden sv Installation och bruksanvisning 2 7 en Installation and Instructions for Use 8 13 de Installations und Betriebsanleitung 14 19 fi Asennus sa K ytt ohje 20 25 en Wiring diagram 26...

Страница 2: ...g r att batterierna ska vara fullt uppladdade innan l ngre avst llning av sl pet trailern sker Vid mer n 1 m nads avst llning ska kabels kringen vid batterierna tas bort Garanti och funktion P LIGHT...

Страница 3: ...terstart kr vs 5 minuters sp nning p plint 4 och 6 lastbilen tillkopplad och belysning p Om sp nningen i batterierna efter denna tid verstiger programmerad gr ns aktiveras plint 10 AUX igen Viktigt a...

Страница 4: ...av P LIGHT vid korttidsparkering OBS F r inte vara ihopkopplad med kablage som r kopplat till plint 4 eller 6 6 In 24V Belysningskrets 2 min 2 5 mm Fr n sl pets kopplingshandske 7 Ut 24V Belysningskr...

Страница 5: ...mm2 4 2 5 mm2 6 2 5 mm2 Ut 5 Max 100W 7 Max 100W 9 Max 200W 30 31 och 32 Max 200W 34 Jordpunkt kra PTO 41 Kra u ag PTO Solenoid max 100A eller Rel max 50A Ba erikapacitet 45Ah Sp nning 24V Laddning 10...

Страница 6: ...9 25 In 24V fr n tryckknapp 1 Parkering aktiverar plint 5 och 7 26 Ut 24V till tryckknapp 1 Parkering aktiverar plint 5 och 7 30 Ut 24V momentan vippstr mbrytare f r styrning av solenoid 1 fr mre kap...

Страница 7: ...i XL Maxi XL HyCover 58 R 58 L Kopplingsbox p sl p 31 AUX 32 30 Utg belysnings krets 1 Utg belysnings krets 2 58 R 58 L 9 6 4 7 5 3 Solenoid 1 och 2 Styrenhet 10A support p light com 3 InnoNet AB 2019...

Страница 8: ...e fully charged before the trailer taken out of service for any length of time If it is to be taken out of service for more than 1 month the cable fuse at the batteries must be removed Warranty and fu...

Страница 9: ...ing requires 5 minutes of voltage on terminals 4 and 6 truck connected and lighting on If the voltage in the batteries after this time exceeds the programmed limit terminal 10 AUX is activated again I...

Страница 10: ...erm parking NOTE Must not be connected to cabling connected to terminal 4 or 6 6 Input 24 V Lighting circuit 2 min 2 5 mm From the trailer s hitch 7 Output 24 V Lighting circuit 2 connected to parking...

Страница 11: ...58 L 9 6 4 7 5 3 Solenoid or Relay Control unit 10A U T R U S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2 5 mm2 4 2 5 mm2 6 2 5...

Страница 12: ...Option activates terminal 9 25 Input 24 V from pushbutton 1 Parking activates terminals 5 and 7 26 Output 24 V to pushbutton 1 Parking activates terminals 5 and 7 30 Output 24 V momentary rocker switc...

Страница 13: ...ver tarp coverage with P LIGHT Maxi XL Connection Maxi XL HyCover ngsg rden www p light com established 2000 46 581 80 300 Maxi XL HyCover 58 R 58 L Clutch box on trailer 31 AUX 32 30 58 R 58 L 9 6 4...

Страница 14: ...lieger f r einen l ngeren Zeitraum abgestellt wird Betr gt die Abstelldauer mehr als 1 Monat muss die Kabelsicherung an den Batterien entfernt werden Gew hrleistung und Funktion F r P LIGHT bieten wir...

Страница 15: ...C11 angezeigt F r den Neustart ist eine 5 min tige Spannung an Klemme 4 und 6 erforderlich Lkw angeschlossen und Beleuchtung eingeschaltet WenndieSpannungindenBatteriennachdieserZeit die programmiert...

Страница 16: ...leuchten soll HINWEIS Darf nicht mit Kabeln verbunden sein die an Klemme 4 oder 6 angeschlossen sind 6 24 V Eingang Beleuchtungsstromkreis 2 mind 2 5 mm Vom Kupplungskopf des Anh ngers 7 24 V Ausgang...

Страница 17: ...58 L 31 AUX 32 30 58 R 58 L 9 6 4 7 5 3 Solenoid or Relay Control unit 10A U T R U S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2...

Страница 18: ...2 Option aktiviert Klemme 9 25 24 V Eingang von Drucktaste 1 Parken aktiviert Klemme 5 und 7 26 24 V Ausgang an Drucktaste 1 Parken aktiviert Klemme 5 und 7 30 24 V AusgangWippschalterzurSteuerungvonM...

Страница 19: ...9 6 4 7 5 3 Solenoid 1 och 2 Control unit 10A support p light com 3 InnoNet AB 2019 We reserve the right to correct any printing errors and ypographical errors and reserve the right to make changes w...

Страница 20: ...en tulee pidemm n seisokin ajan olla t yteen ladattuja Yli 1kk seisokin ajaksi tulee akkujen lataussulake poistaa Takuu ja toiminta P LIGHT my nt 1 vuoden tuotetakuun Takuua sioissa tulee noudattaa In...

Страница 21: ...etason nasta 10 AUX sammuu ja n yt lle tulee ilmoitus C11 Uudelleenk ynnistys vaatii j nnitteen nastalle 4 ja 6 viiden minuutin ajaksi auto kytkettyn ja valot sytytettyin Jos akkujen j nnite t m n j l...

Страница 22: ...a sek P LIGHTin toimesta lyhytaikaisessa pys k inniss HUOM Ei saa yhdist liittimien 4 tai 6 johtimiin 6 Tulo 24V Valaisinpiiri 2 min 2 5 mm2 Per vaunun pistokkeelta 7 L ht 24V Valaisinpiiri2 kytket np...

Страница 23: ...S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2 5 mm2 4 2 5 mm2 6 2 5 mm2 Out 5 Max 100W 7 Max 100W 9 Max 200W 30 31 och 32 Max 20...

Страница 24: ...24V painonappi 1 Pys k inti aktivoi liittimet 5 ja 7 26 L ht 24V painonappi 1 Pys k inti aktivoi liittimet 5 ja 7 30 L ht 24V vipukytkin solenoidille 1 Etupeite tehdaskytketty liittimelt 31 31 L ht 24...

Страница 25: ...over 58 R 58 L Clutch box on trailer 31 AUX 32 30 58 R 58 L 9 6 4 7 5 3 Solenoid 1 och 2 Control unit 10A support p light com 3 InnoNet AB 2019 We reserve the right to correct any printing errors and...

Страница 26: ...www p light com established 2000 Wiring diagram 26 25 23 GR 31 30A 30B 32A 32B A B D C Plintar i Terminal in P LIGHT Maxi XL Option Parking Gnd AUX 30A 32A...

Страница 27: ...www p light com established 2000 Wiring diagram 27 25 23 GR 31 30A 30B 32A 32B A B D C Plintar i Terminal in P LIGHT Maxi XL Option Parking Gnd AUX 30B 30A 32A 32B F2 auto fuse 42 41...

Страница 28: ...hout prior notification Manufacturer InnoNet AB Olv gen 7 SE 342 50 Vislanda Phone 46 472 483 83 www p light com www innonet se Mounted date Manufactory No Trailer Company City Country Sign Manufactor...

Отзывы: