Elektronics Maxi XL HyCover
Elektronic terminals
Terminal no.
Description
1. B24 V, connected to P-LIGHT battery.
2. Battery Gnd (-), connected to P-LIGHT battery.
3. Input Gnd (-) negative/ground, min 2.5 mm². From vehicle/
trailer hitch.
4. Input +24 V “Lighting circuit 1”, min 2.5 mm². From the trailer’s
hitch.
5. Output +24 V “Lighting circuit 1”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
6. Input +24 V “Lighting circuit 2”, min 2.5 mm². From the trailer’s
hitch.
7. Output +24 V “Lighting circuit 2”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
8. Input +24 V “Option”. (Direct operation to terminal 9, if, for
example, you connect the warning light to terminal 9, it’s
possible to connect the trailer’s reversing circuit here, this
activates the warning light when the vehicle reverses).
9. 24 V “Option” e.g. warning light, work lighting, etc.
max. 200 W. Activated by push button 2.
10. Output +24 V “AUX”. Always +24 V even if the truck is not
connected, nor controlled by any pushbutton. Is intended for
operation of e.g. external radio control, the cable is prepared
up to the rocker switch where you connect the required
equipment. Max 200 W. Factory connected to terminal 31.
21 and 22. No function.
23. Input +24 V from pushbutton 2 “Option” (activates terminal 9).
24. 24 V to pushbutton 2 “Option” (activates terminal 9).
25. Input +24 V from pushbutton 1 “Parking” (activates terminals
5 and 7).
26. 24 V to pushbutton 1 “Parking” (activates terminals
5 and 7).
30. 24 V momentary rocker switch for control of solenoid
1 front tarp (factory connected from terminal 31).
31. 24 V to toggle switch for external radio control (factory
connected from terminal 10).
32. 24 V momentary rocker switch for control of solenoid
2 rear tarp (factory connected from terminal 31).
34. Ground point power Gnd(-), factory connected to solenoids
terminal A.
41. Output +24 V power (PTO), connected to Terminal D on
solenoids.
42. Connected to terminal 43 (main power switch, factory
connected).
43. Factory connected to terminal 42, MCB.
44. Cable to battery’s positive terminal (+) (factory connected).
F1. Power fuse (PTO) 80 A.
Connection HyCover
Solenoid 1 Front tarp
Terminal 1.
+24 V factory connected to rocker switch 30.
Terminal 2.
Gnd (-) factory connected to 34.
Terminal 3.
+24 V factory connected to rocker switch 30.
Terminal A.
Gnd (-) factory connected to 34.
Terminal B.
Output to DC motor front tarp.
Terminal C.
Output to DC motor front tarp.
Terminal D
+24 V factory connected to MCB 41.
Solenoid 2 Rear tarp
Terminal 1.
+24 V factory connected to rocker switch 32.
Terminal 2.
Gnd (-) factory connected to 34.
Terminal 3.
+24 V factory connected to rocker switch 32.
Terminal A.
Gnd (-) factory connected to 34.
Terminal B.
Output to DC motor rear tarp.
Terminal C.
Output to DC motor rear tarp.
Terminal D
+24 V factory connected to MCB 41.
NOTE! If the motor runs in the wrong direction after connection,
change positions of B and C or directly on the motor
Connection Radio
For connection of the radio use separate terminals, see further
instruction in the enclosed appendix.
Terminal to solenoid 1 och 2