O
ZRAY
Pollux Small Series – 16M Camera
Page
36
of
40 Manual 1.2
•
Acquisition Mode : Select of Image Acquisition Mode
-
0 : Free Running - Continuous Image Acquisition
-
1 : External Trigger Timed - Trigger is used Start of Frame.
-
2 : External Trigger Width - Trigger is used Start of Frame and Exposure.
•
Trigger Mode : Select of Trigger Input
-
0 : Async. Ext Trigger (CC1) - Trigger Input via Frame Grabber.
-
1 : Async. Ext Trigger (6-pin) - Trigger Input via Hirose Connector.
•
Frame Rate : Set the Frame Rate per Second
-
Range :
MIN : 1.0 fps,
MAX : 47.0 fps (10-tap), 40.0 fps(8-tap), 20.0 fps(4-tap),
15.0 fps(3-tap), 10.0 fps (2-tap)
•
Exposure Time : Set Exposure Time & Change Exposure Time depends on
Frame Rate
-
Range :
MIN : 100 μs
MAX : 20,889 μs (10-tap), 24,739 μs(8-tap), 49,807 μs(4-tap),
66,191 μs (3-tap), 99,614 μs(2-tap)
•
Data Depth : Select Bit of Image Output
-
7 : 10-tap 8bit - 6 : 8-tap 8bit
-
5 : 4-tap 10bit - 4 : 4-tap 12bit - 3 : 4-tap 8bit
-
2 : 3-tap 8bit - 1 : 2-tap 12bit
- 0 : 2-tap 10bit
•
Programmable Gain : Analog Gain Control
•
Digital Gain : Digital Gain Control
•
Test Patten on/off
•
Dot : Bad Pixel Correction
•
PRNU : Photo Response Non-Uniformity Correction
•
ROI : Execute Image Region of Interest
-
We recommend using the Pollux terminal at the bottom of the program.
-
Start X coordinate (0 ~ 3840 : Input multiple of 16)
-
Start Y coordinate (0 ~ 3840: Input multiple of 2)
-
Width (208 ~ 4096 : Input multiple of 16)
-
Height (208 ~ 4096 : Input multiple of 2)
Figure 21.
Run Pollux terminal
Содержание pollux PX12M64MCL
Страница 1: ......
Страница 19: ...OZRAY Pollux Small Series 16M Camera Page 19 of 40 Manual 1 2 Figure 10 Installation using PoCL ...
Страница 33: ...OZRAY Pollux Small Series 16M Camera Page 33 of 40 Manual 1 2 ...
Страница 37: ...OZRAY Pollux Small Series 16M Camera Page 37 of 40 Manual 1 2 Figure 22 Setting ROI at Pollux terminal ...