O
ZRAY
Pollux Small Series – 16M Camera
Page
29
of
40 Manual 1.2
4.6.2
Command List
Parameter input type
I = Integer value
H = Hex integer value
F = Float value
S = Strings
Command
Parameter Default
Description
h
None
Help Description
gcp
None
Check all the setting value of parameter
gcv
None
Check Firmware Version
gcfv
None
Check FPGA version
gseri
None
Check Camera Serial Number
rds
INT
0
Set start up read user region
wus
INT
0
Save the setting value in User region
Range : 0 ~ 7
rus
INT
0
Load the setting value in User region
Range : 0 ~ 7
exp
INT
20889
Exposure time setting
Unit : micro-second
Minimum : 100 μs
Maximum :((1/50Mhz)*LineLength*Height*1000000
) * (fmax /frate) μs
Range
MIN : 100 μs
MAX : 20,889 μs (10-tap), 24,739 μs (8-tap)
49,807 μs (4-tap), 66,191 μs (3-tap)
99,614 μs (2-tap)
emax
None
Read max exposure time for current frame rate.
frate
INT
47
Frame rate setting
<Range>
MIN : 1 fps
MAX : 43fps(10-tap), 40fps(8-tap)
20fps(4-tap), 15fps(3-tap), 10fps(2-tap)
fmax
None
Read Max Frame Rate
otap
INT
1
Output Bit Depth Setting
7 : 8-tap 8-bit, 6 : 10-tap 8-bit
5 : 4-tap 12-bit, 4 : 4-tap 10-bit, 3 : 4-tap 8-bit
2 : 3-tap 8-bit, 1 : 2-tap 12-bit, 0 : 2-tap 10-bit
Table 11.
Command List 1