SZ SERIES
/
11
APPENDIX B - PERSONAL SAFETY AND EQUIPMENT DAMAGE CONCERNS
Flushing Ozone from the System
NOTE: In most circumstances, a very small amount of ozone will be contained within the system after shut-down
and therefore exposure will be minimal.
Eventually the ozone (even while in the system) will safely revert back to oxygen, but in the right conditions the
ozone can remain in the system for 24 hours or even longer. In the event that maintenance must be performed
on the components in contact with ozone, the following is recommended for reducing the possibility of exposure
to the ozone:
•
Whenever possible it is recommended that the machine run with maximum permissible air flow for at least 10
minutes with the Ozone Generator OFF in order to flush out most residual ozone.
• If the machine cannot be operated prior to maintenance or repair, a waiting period of 12 to 24 hours (if ozone
has been produced recently) is recommended to allow the ozone to decay by reverting back into oxygen.
Isolating energy sources
The SinkZone has electrical and mechanical hazards, and maintenance or repair should not take place unless all
energy sources have been turned off, disconnected, and/or drained.