SAFETY PRECAUTIONS

Ozone is a powerful oxidizing agent. Observe strict 

operating procedures while using ozone equipment. 

It is imperative that only ozone compatible materials 

are used in conjunction with the ozone system. 

Ensure that the Ozone Generator is in a well-ventilated 

area. Do not allow rain or condensation to contact the 

Ozone Generator. The Ozone Generator is not weather 

proof. The unit must be operated indoors or in an 

enclosure in a non-condensing environment. 
Carefully review and familiarize yourself with the 

following important safety information concerning the 

Ozone Generator:
1.  Ozone is an extremely aggressive and powerful 

oxidizer. The Occupational Safety and Health 

Administration (OSHA) 8 hour exposure limit is 

0.10 PPM. The OSHA 15 minute exposure limit for 

ozone is 0.3 PPM. Above 0.3 PPM, there is the risk 

of damage to respiratory tissues.

2.  People who have no sense of smell should not 

operate this equipment. 

3.  Never attempt to verify ozone production by directly 

breathing or smelling the ozone outlet.

4.  The Ozone Generator contains high voltages. 

Unauthorized entry can result in serious injury or 

death. For service instructions, contact Ozone 

Solutions.

5.  Make sure all connections are secure and are 

not leaking. Failure to do so could result in the 

discharge of ozone into an undesired space.

Do not attempt to modify or enhance the performance 

of the Generator in any way.

INTRODUCTION

This ozone generator produces ozone gas from 

atmospheric air.  Oxygen is very unstable in its tri-

atomic form (ozone) and naturally attaches to most 

organic chemical contaminants, mold spores, odors, 

etc., leaving them oxidized and broken down 

molecularly. This reaction sanitizes the surfaces it 

comes in contact with. 

THEORY OF OPERATION

When the machine is turned on, the ozone generator 

will begin producing ozone, the solenoid valve will open, 

and the internal water pump will begin pumping water 

through the ozone injector.  This will create a vacuum 

pressure on the ozone lines pulling air into the system 

and injecting ozone into the water.
This ozone generator produces ozone from ambient 

air around the machine.  The air is pulled in through a 

desiccant air dryer cartridge (to remove moisture), then 

into the generation module.  The generator uses a form 

of controlled spark, called a corona, to split oxygen 

molecules into the atomic O

-

 ion.  Some of the ions re-

bond with regular oxygen molecules to form ozone. 
Water that has been injected with ozone travels through 

an extended contact vessel, which includes a static 

mixer cartridge, to allow the ozone a chance to properly 

mix with the water.  The ozonated water then leaves the 

machine and goes on to the point of use.

O

2

O

2

O

2

O

-

O

-

O

3

+

+

NOTE:

 If the operator has asthma, he or she must 

not  enter  an  airspace  that  has  a  significant  ozone 

concentration. Ozone can induce an asthma attack.

Содержание SINKZONE

Страница 1: ...SINKZONE FOOD AND HAND WASH OZONE GENERATOR MODEL SinkZone INSTALLATION OPERATIONS MANUAL 451 Black Forest Road Hull Iowa 51239 USA P 712 439 6880 F 712 439 6733...

Страница 2: ......

Страница 3: ...Introduction 4 Theory of Operation 4 SECTION 2 Installation Guidelines 5 Location 5 External Components 5 Specifications 5 Internal Components 6 SECTION 3 Water Flow 6 Water Pressure 6 Air Dryer Desic...

Страница 4: ...to an undesired space Do not attempt to modify or enhance the performance of the Generator in any way INTRODUCTION This ozone generator produces ozone gas from atmospheric air Oxygen is very unstable...

Страница 5: ...the water The flow can be regulated via the needle valve attached 2 Power Switch This power switch turns on all aspects of the machine includinggenerator pump solenoidvalve andpressure switches This s...

Страница 6: ...ates a low pressure which sucks in ozone This vacuum pressure is what drives the air and ozone flow through the rest of the system 7 Pressure Switch The pressure switches ensure that water pressure re...

Страница 7: ...nerate the media after every 75 hours of run time regardless of incoming air moisture content To regenerate the desiccant media 1 Remove the desiccant cartridge from its bracket inside the SinkZone ma...

Страница 8: ...or shipping a product back to us Failure to get prior authorization may result in denial of your claim Once authorized you may return the defective equipment to Ozone Solutions with the transportatio...

Страница 9: ...9 INSTALLATION OPERATIONS MANUAL CONTACT INFORMATION Ozone Solutions Inc 451 Black Forest Road Hull IA 51239 USA Phone 712 439 6880 Fax 712 439 6733 Email sales ozonesolutions com Website www ozonesol...

Страница 10: ...CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF OZONE SOLUTIONS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF OZONE SOLUTIONS IS PROHIBITED PROPRIETARY AND CONFIDENTIAL EN...

Страница 11: ...act with ozone the following is recommended for reducing the possibility of exposure to the ozone Whenever possible it is recommended that the machine run with maximum permissible air flow for at leas...

Страница 12: ...12 SZ SERIES APPENDIX C SAFETY DATA SHEET...

Страница 13: ...SZ SERIES 13 INSTALLATION OPERATIONS MANUAL This page left blank for booklet printing purposes...

Страница 14: ...14 SZ SERIES OZONE SOLUTIONS This page left blank for booklet printing purposes...

Страница 15: ...SZ SERIES 15 INSTALLATION OPERATIONS MANUAL This page left blank for booklet printing purposes...

Страница 16: ...12 439 6880 F 712 439 6733 E sales ozonesolutions com www ozonesolutions com 2018 Ozone Solutions All Rights Reserved Ozone Solutions is a registered trademark This publication may not be reproduced i...

Отзывы: