SZ SERIES
/
5
INSTALLATION & OPERATIONS MANUAL
SECTION 2
INSTALLATION GUIDELINES
It is recommended that the ozone generator be located
indoors in a well ventillated area not far from the
point of use. Dry ambient air will improve generator
performance and reduce the frequency of service for the
desiccant and generator module. Room temperature
or cooler ambient conditions will also allow for better
performance and longevity of the system.
LOCATION
The system is designed as a fixed, wall-mountable,
indoor unit, and will also operate free-standing on
level surfaces. For proper operation and safety of the
equipment, it should only be operated in areas without
excessive dust, debris, and spray.
EXTERNAL COMPONENTS
1. Oxygen Flow Meter with Needle Valve
This flow meter displays the rate of oxygen flowing
through the system and into the water. The flow can be
regulated via the needle valve attached.
2. Power Switch
This power switch turns on all aspects of the machine,
including generator, pump, solenoid valve, and pressure
switches. This switch is operated only as ON or OFF.
3. Fuse Holder
This cartridge contains the power fuse in the system. If
too much current is drawn by the machine, the fuse will
burn out and will need to be replaced.
4. Ventillation Filters
These vents contain a small destruct block that
prevents larger airborn particles from passing through,
as well as aiding in the destruction of any off-gassed or
leaked ozone gas.
5. Power Cable
The power cable to the ozone generator will be mounted
through this cord grip.
6. Water Connections
These bulkhead fittings are the water in and ozonated
water out fittings. They are both threaded, 1/2” NPT
brass fittings.
SPECIFICATIONS
SZ-Series
Required Volts
Amps @ 120V
Amps @ 240V
Power
(Watts)
Dimensions - WxDxH
(inches)
Weight
(lbs)
SinkZone
120-240
0.3
0.15
230
20x20x10
40
1
2
3
6
5
4
GFCI Circuit Required!
Содержание SINKZONE
Страница 2: ......
Страница 12: ...12 SZ SERIES APPENDIX C SAFETY DATA SHEET...
Страница 13: ...SZ SERIES 13 INSTALLATION OPERATIONS MANUAL This page left blank for booklet printing purposes...
Страница 14: ...14 SZ SERIES OZONE SOLUTIONS This page left blank for booklet printing purposes...
Страница 15: ...SZ SERIES 15 INSTALLATION OPERATIONS MANUAL This page left blank for booklet printing purposes...