THE CHARGING PROCESS: LEAD ACID

 (Gel, Calcium SMF, AGM&WET/EFB)

1)  Qualification - Battery Condition Check

When the charger is first switched on it checks the battery condition to determine whether the 

battery needs reconditioning. During this qualification process it checks the internal impedance 

and initial voltage of the battery and it will determine how much charge current, if any that the 

battery will accept. 

2)  Automatic Enhanced Battery Rejuvenation - Blue Charging LED Double Flash

If the initial qualification detected that the battery was in poor condition, the patented 

rejuvenation process will begin automatically. During the rejuvenation process a high voltage 

equalising and peak pulse reconditioning charge is used to repair the sulphated battery. 

This unique patented feature will break down and dissolve the lead-sulphate crystal build up 

on the battery plates which will extend the life of your battery. It can also balance out high 

concentrations of acid. The equalisation voltage will be 16V maximum. If the battery voltage 

doesn’t reach 9V within 24 hours, the Rejuvenation process will time out.

Manual  Enhanced Rejuvenation Mode

To manually rejuvenate your batteries, simply press and hold both the Battery Type and Charge 

Rate buttons simultaneously for 3 seconds until the Blue Bulk LED flashes (Double flash). This 

mode will last for 24 Hours. To stop rejuvenation mode, press and hold both the Battery Type 

and Charge Rate buttons simultaneously for 3 seconds until the Blue Bulk LED stops flashing 

rapidly.

Important Note:

 Please check your Battery Type and Charge Rate selection to ensure you 

haven’t accidentally changed these settings.

3)  Soft Start Charging - Blue Charging LED Flashing Slow (Single Flash)

Gently charges the battery using a reduced charge output until the battery voltages reaches 

11V. If the battery voltage doesn’t reach 11V within 6 hours, the safety timer protection will stop 

the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing.

4)  Bulk Charging - Blue Charging LED ON

 

(Charge Voltage depends on battery type selection)

Uses the maximum selected charge output until the battery voltage reaches 14.1/14.4/14.7V. If 

the battery voltage doesn’t reach this within 24 hours, the safety timer protection will stop the 

unit from charging and the Red Fault LED will start flashing and the Blue Bulk LED will be ON.

5)  Absorption Charging - Blue Charging LED ON and Green Full LED Flashing

Uses a constant voltage while reducing the charging output current to ensure the battery 

receives a full charge without overcharging the battery. 

6)  Equalisation Charging - Blue Charging LED and Green Full LED both flashing 

A well proven process that carefully overcharges the battery to restore it’s full capacity. The 

Equalisation stage for CALCIUM Battery type selection is automatic. The Equalisation stage for 

AGM&WET(EFB) and GEL Battery Types only occurs if the initial start voltage is below 11 Volts.

7)  Battery Analysis - Green Full LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 

completed. If the battery voltage drops too quickly during the analysis mode, this means the 

battery is probably faulty.  If the battery analysis failed, this is indicated by the Green Full LED 

flashing.

8)   Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well maintained 

and kept 100% fully charged. Float mode will maintain the battery at a constant 13.6V. 

9)   Long Term Maintenance - Full Green LED ON

During long term maintenance / float mode, the unit will apply a special pulse charge to ensure 

the battery is kept in optimal condition. 

Содержание OC-PRO2500L

Страница 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC PRO2500L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...ice agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the ey...

Страница 3: ...ully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance...

Страница 4: ...tery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the se...

Страница 5: ...age 13 6V lead acid type batteries only Power Supply Output 13 8VDC 25A Max StartVoltage 2V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Temp Compensation...

Страница 6: ...he unit is turned on as per STEP 1 Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out...

Страница 7: ...ing Slow Single Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protectio...

Страница 8: ...1 Blue Charging LED ON and Green Full LED Flashing Uses a constant voltage of 14V while reducing the charging output current to ensure the battery receives approximately 90 charge without overcharging...

Страница 9: ...rging Time Out Error ON OFF ON ON Flash Reverse Polarity or Short Circuit Error OFF OFF ON ON ON Final Analysis Sulphation Shorted cell check fail OverTemperature Protection OFF OFF ON ON Flash Power...

Страница 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVE...

Страница 11: ...ttery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Charging LED is ON Flashing with Fault LED flashing Battery Ah capacity...

Страница 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...

Отзывы: