background image

10 • Oz Charge manual  

www.ozcharge.com.au

TROUBLE SHOOTING

Problem

Indication

Possible Causes Suggested Solution

Charger does not 

work?

No Indicator 

lights on

- No AC power

- Check AC connections and 

make sure the AC Power Point is 

switched ON.

- Try a different AC Power Point 

which you know is working.

Charger has no DC 

output?

Fault Red LED 

is ON

- Output is short 

circuited

- Reverse polarity 

protection

- Loose / bad 

connection to the 

battery

- Check DC connection between 

charger and battery and make 

sure they are not short circuited. 

(Touching each other)

- Check that the crocodile clips 

have not fallen off or come loose.

- Check that the crocodile clips/

ring terminals are connected to 

the correct polarity.

Note: 

The charger output is only 

present when connected to a 

battery.

No charging current? Fault Red LED 

is Flashing

- Battery is severely 

sulphated

- Battery has a 

damaged cell

- Overheat 

protection mode

- Check the battery condition, 

age etc.

- Battery may need replacement.

- Move battery & charger  to a 

cooler environment.

The full / float light 

won’t come on.

Fault Red LED 

is Flashing

or

Full Green LED 

is Flashing

Charging LED 

is ON/Flashing 

with Fault LED 

flashing

- Battery Ah 

capacity too large 

for the battery 

charger and it has 

timed out

- Battery is 

defective

- Battery is severely 

sulphated

- Check the charger 

specifications match the battery 

capacity. Eg. make sure battery 

capacity is not too big for the 

charger.

- Battery may need replacement.

- Charge rate selected might be 

too low for the battery. Switch 

charger off and on and try again 

or try a higher charge rate setting 

providing it doesn’t exceed the 

maximum charge limit for your 

battery.

NOTE:

 If the Battery Type and Charge Rate LED’s are both flashing, this indicates no battery is detected 

and the unit is in Eco Power Saving mode. If a battery is connected the voltage maybe to low (below 

2V) for the charger to start. Otherwise check all connections from the charger to the battery.

OPTIONAL / REPLACEMENT PARTS

This unit supports a wired LCD Remote Display.  
Model: OC-PRORDP.
For the full range of replacement parts and accessories, 
please visit our website:
 www.ozcharge.com.au / www.ozcharge.co.nz

Содержание OC-PRO2500L

Страница 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC PRO2500L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...ice agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the ey...

Страница 3: ...ully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance...

Страница 4: ...tery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the se...

Страница 5: ...age 13 6V lead acid type batteries only Power Supply Output 13 8VDC 25A Max StartVoltage 2V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Temp Compensation...

Страница 6: ...he unit is turned on as per STEP 1 Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out...

Страница 7: ...ing Slow Single Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protectio...

Страница 8: ...1 Blue Charging LED ON and Green Full LED Flashing Uses a constant voltage of 14V while reducing the charging output current to ensure the battery receives approximately 90 charge without overcharging...

Страница 9: ...rging Time Out Error ON OFF ON ON Flash Reverse Polarity or Short Circuit Error OFF OFF ON ON ON Final Analysis Sulphation Shorted cell check fail OverTemperature Protection OFF OFF ON ON Flash Power...