background image

2 • Oz Charge manual   

www.ozcharge.com.au

• 

Patented battery rejuvenation (reconditioning).

• 

Battery voltage retention analysis.

• 

Ultra lower power consumption (ECO Mode)

• 

Multi Stage:  Lead-acid type batteries (Gel, Calcium SMF, AGM, WET, EFB )

1 - Qualification - Battery condition check

2 - Battery rejuvenation (recondition mode)

3 - Soft start charging

4 - Bulk charging

5 - Absorption charging

6 - Equalisation charging

7 - Battery analysis

8 - Float mode 

9 - Long term maintenance pulse charge. Recharge Cycle every 21 Days.

• 

Multi Stage: Lithium-ion (LifePO4) type batteries

1 - Lithium Activation

2 - Soft start charging

3 - Bulk charging

4 - Absorption stage 1

5 - Absorption stage 2

6 - Full / Analysis

• 

Automatic diagnosis and charge:

 On power up, the charger will automatically diagnose the 

battery condition and determine if the rejuvenation mode (reconditioning) or charge cycle is 

required.

• 

Patented battery rejuvenation technology:

  The charger has a unique and patented reju-

venation feature which uses high voltage equalising and peak pulse reconditioning to repair 

sulphated batteries. This feature is fully automatic and depends on the internal impedance of 

the battery. It also depends on whether the battery is still connected in the vehicle.

• 

Can be left on 24/7 to ensure your battery is always maintained and fully charged: 

The 

battery charger can be left unattended and left permanently connected all year round. The 

intelligent charger will monitor the battery voltage and will maintain it at peak performance.

• 

Short circuit and reverse polarity protection: 

• 

Heavy-duty and corrosion-resistant output connectors:

• 

Crocodile clips and ring terminals: 

It comes with a quick connect fly lead and 2 different 

kinds of connectors, crocodile clips and ring terminals. The ring terminals are integrated into 

the crocodile clip harness and are perfect for permanent connection to your battery. You can 

connect the ring terminals to the battery and tuck the lead away while you are using your 

vehicle and when you get back to your garage simply plug the lead back into the charger.

 

To detach the crocodile clips from the ring terminal harness, use a phillips head screw driver 

and remove the screws.

 

SELECTABLE CHARGE RATES

• 

Rapid Charge Mode: 

Uses maximum charging current to ensure the fastest charge time. You 

may hear the fan turn on during this mode. 

• 

Silent Charge Mode: 

Charges at a slightly reduced charge rate so the cooling fan is not 

required. 

• 

Maintenance Mode: 

Ideal and recommended for long term maintenance charging or for 

charging smaller batteries. 

• 

Power Supply Mode: 

Press & Hold the Charge Rate button for 3 seconds to activate and de-

activate Power Supply Mode. When in Power Supply Mode, the Power  Supply Mode LED and 
25A LED will be ON. Power supply mode is only required if you don’t have any batteries.

Содержание OC-PRO2500L

Страница 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC PRO2500L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Страница 2: ...ice agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the ey...

Страница 3: ...ully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance...

Страница 4: ...tery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the se...

Страница 5: ...age 13 6V lead acid type batteries only Power Supply Output 13 8VDC 25A Max StartVoltage 2V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Temp Compensation...

Страница 6: ...he unit is turned on as per STEP 1 Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out...

Страница 7: ...ing Slow Single Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protectio...

Страница 8: ...1 Blue Charging LED ON and Green Full LED Flashing Uses a constant voltage of 14V while reducing the charging output current to ensure the battery receives approximately 90 charge without overcharging...

Страница 9: ...rging Time Out Error ON OFF ON ON Flash Reverse Polarity or Short Circuit Error OFF OFF ON ON ON Final Analysis Sulphation Shorted cell check fail OverTemperature Protection OFF OFF ON ON Flash Power...

Страница 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVE...

Страница 11: ...ttery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Charging LED is ON Flashing with Fault LED flashing Battery Ah capacity...

Страница 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...

Отзывы: