“talking”. 

2).a. If there is no response signal with 4S from called handset monitor, after 4 

“Di  Di  Di  Di”  tones,  the  handset  will  exit  the  call  status  and  return  to  standby 

status.   

        b. If receiving a response signal with 4S from the called handset monitor, 

then the calling handset monitor will play the selected ring tone, then the called 

handset will display “talking” and play its selected ring tone. The indicator light 

will remain lit. 

3). a. If no one answers the call from called handset monitor, the call will last 

60S and enter to the standby status. 

      b. If some one answers the call from called handset monitor, then it will stop 

playing  the  ring  tone  and  enter  the  “Talking”  status  (the  indicators  in  both 

handset  monitors  will  turn  from  red  to  green  and  remain  lit),  the  talk  time  is 

120S. 

      c. Meanwhile, if pressing the “

  ” button in calling handset monitor, then it 

will end the call and enter into the standby status.   

4).In the process of paging, the user can press the “

  ” button again in any 

handset monitors to end the communication, then it will enter the standby status 

after hearing two “Du Du”. 

Note:  If  the  handset monitor  is  short  of power,  then  it  will indicate  the  user to 

charge the battery in handset monitor.     

 

      Night-vision operation 

 

1). When the handset is in talking status, press the “

” button to activate the 

night-vision of outdoor camera. 

2).  When  the  handset  is  in  surveillance  status,  press  the  “

  ”  button  to 

activate the night-vision of outdoor camera.   

 

    RFID card-reader operation: 

It  is  used  to  register  two  management  cards  (one  is  to  add  cards,  one  is  to 

delete  cards),  20pcs  user  cards  and  20pcs  shadow  cards;  being  compatible 

with EM4001; 

 

Initialization: Which is used to set 2pcs management cards (one is to add cards, 

one is to delete cards) and 20pcs shadow cards (The exact cards depend on 

the client’s request, maximum 20pcs users' cards). 

      Initialization  procedure:  Press  the  Initialization  button  within  the  battery 

cover, then it will buzz and the red indicator will flash. In initialization status, the 

operation procedures as followings: contact

Add cards

Delete cards

Shadow cards 1

Shadow cards 20

,then all the user cards will be deleted. 

During  this  period,  if  you  press  the  initialization  button  again  or  wait  for  30S 

Содержание Wireless video intercom

Страница 1: ......

Страница 2: ...Oz View Technical Manual V1 02 1st Jan 2011 2 ...

Страница 3: ...ption 3 Handset cradle 5 Charger fixing procedure 5 Button description 6 ID NO display 6 Coding 6 Receive code 7 Code clearing 8 Setting of ring tone 8 Brightness adjustment 8 Surveillance 9 Basic operation 10 Night vision operation 11 RFID card reader operation 11 Unlocking time setting 12 Installation 13 Wiring of in line PSU power adaptor 13 Lock connection 14 Technical specifications 15 Troubl...

Страница 4: ...veillance mode function Built in back up battery for call station Still can work if power failure Optional built in RFID card readers Components checklist Package contents One outdoor camera call station Including Li ion rechargeable battery one handset monitor Including Li ion rechargeable battery one power adaptor for call station one charger for handset monitor cradle and screws for fixing the ...

Страница 5: ...Oz View Technical Manual V1 02 1st Jan 2011 5 Products description ...

Страница 6: ...Oz View Technical Manual V1 02 1st Jan 2011 6 Handset cradle 1 Desk mounted 2 Wall mounted ...

Страница 7: ...Oz View Technical Manual V1 02 1st Jan 2011 7 Charger fixing procedure ...

Страница 8: ...is in the OFF status until the 2 4 inch TFT LCD displays Welcome and sounds two Di Di tones then release the button It means that the handset monitor is entering into the ON status Press and hold the ON OFF button when the handset monitor is in ON status then the 2 4 inch TFT LCD will show Goodbye and create two Di Di tones then release the button This indicates that the handset monitor is enterin...

Страница 9: ...ive code status then press the button at this time in 2nd handset monitor If it shows success on the handset it means that the coding has been successful Adding one more outdoor call station 1 Press the and buttons when the handset is in the ON status until the screen shows transmit code then release the buttons and enter the transmit code status 2 Then press and hold the call button in outdoor ca...

Страница 10: ...s At the same time then press the ON OFF button in the handset monitor together until the screen displays clear code and creates one Di sound still keep pressing the and buttons when you press the ON OFF button This means that code clearing is successful It will be in OFF status after releasing the buttons You can also press the button to carry out the code clearing Outdoor call station Press the ...

Страница 11: ...door call station receives a signal within 1S then it will display the outdoor station if not receiving the signal within 4S then it will auto exit the monitor status 3 In monitor status press the button again and then it will exit the monitoring of outdoor call station The monitor time is 60S After 60S it will auto exit the monitor status One to two or two to two system 1 Press the button when th...

Страница 12: ... call station then the power indicators will light 2 a If not receiving a response signal within 4S then it will sound Di Di Di Di and end the call status and return to the standby status b If receiving a response signal from any handset monitors then the handset will display talking and the outdoor call station will still sound Du Du Then the power indicators of handset will remain lit and play t...

Страница 13: ...ndset monitors to end the communication then it will enter the standby status after hearing two Du Du Note If the handset monitor is short of power then it will indicate the user to charge the battery in handset monitor Night vision operation 1 When the handset is in talking status press the button to activate the night vision of outdoor camera 2 When the handset is in surveillance status press th...

Страница 14: ... followings Contact shadow cards that is corresponding to the user cards then it will delete the user cards During this period if you contact the delete cards again and then it will auto exit the status Note After deleting the user cards then you should re add the new user cards according to the section of ADD USER CARDS Cards unlocking In standby status contact the valid user cards then it will u...

Страница 15: ...all the back Step 2 Install panel 1 Release the call station from back box by removing the locking screw under the front edge of the unit 2 Drill proper wire through holes according to the mounting units 3 Use four screws to fix the installation panel on the wall 4 Connect the cables from wire through holes and square holes of rear panel in the call station When an electric lock is not being conne...

Страница 16: ... Open the front cover of call station power adapter 3 Connecting the AC line to AC INPUT terminal and DC line to DC OUTPUT terminal be careful of the AC DC terminal to avoid of wrong connection 4 Cover the front cover of call station Lock connection ...

Страница 17: ...Oz View Technical Manual V1 02 1st Jan 2011 17 Technical specifications ...

Страница 18: ...Oz View Technical Manual V1 02 1st Jan 2011 18 Trouble shooting ...

Страница 19: ...armored doors or lift shaft comprising metallic components Furthermore radio coverage may also be affected by electrical or electromagnetic interference It is important to test the radio range on the installation site Battery specifications The above marked time is in the specific situation and atmosphere Use the authorized charger only Do not disassemble the batteries Do not short circuit the bat...

Страница 20: ...unction please contact us or our agents 3 Handset monitors should be located where there is a good ventilation dry dustless and not in direct sunlight Don t use the chemical impregnated or wet cloth to clean the products Clean soft dry cloth can be used to clean the products 4 Please install the products according to this instruction manual to avoid of damaging to the products Guarantee One year w...

Отзывы: