background image

 

www.oxygenautomation.com 

 

 

All rights reserved 

Pag

11

 

 

 

 

HYDRAULIC ACTUATORS FOR SWING GATE PARIS 240 RB AND PARIS 240 SB 

Read the instructions carefully before using the product and store them for future use 

GENERAL SAFETY 

The hydraulic operator PARIS, when properly installed and used, guarantees a high degree of safety. 

Some simple rules on behavior can prevent accidental trouble: 

-  Do  not  pass  through  the  leaves  while  they  are  moving.  Before  passing  through  the  leaves,  wait  for  the 
complete opening. 

- Do not stand between the leaves. 

- Do not stop and do not allow children, persons or things to stand there, especially while it is operating. 

- Keep out of the reach of children, remote controls or any other pulse to prevent the automated system 
from being activated involuntarily. 

- Do not allow children to play with the automation. 

- Do not impede the movement of the leaves. 

- Prevent any branches or shrubs from interfering with leaf movement. 

- Maintain efficient and easy to see light signaling systems. 

- Not groped to manually activate the leaves if you have released them. 

-  In  case  of  a  malfunction,  release  the  leaves  to  allow  access  and  wait  for  the  technical  intervention  of 
qualified personnel. 

- Once you have set the manual mode, before restoring normal operation, disconnect the power supply. 

- Do not modify the components of the automation system. 

- Do not attempt to repair or intervene directly and contact only qualified personnel. 

- At least once every six months the automated system, safety devices and the earth connection checked by 
qualified personnel. 

OPERATION MANUAL 

If  you  need  to  operate  the  gate  manually  because  of  a  power  failure  or  malfunction  you  need  to 
temporarily open the release unit. 

- Open the protective cap and insert the supplied key 

-Rotate The key counter-clockwise to unlock. -Rotate The key clockwise to lock. 

Make the maneuver of opening or closing of the leaf. 

N.B .: in NOBLOCK (WOL)  models need to manually release the electric lock. 

Restore the normal operation must be done, after disarming power, turning clockwise the release key until 
it stops. Close the protective cap of the release unit. 

DESCRIPTION 

These instructions are valid for the following models: PARIS 240-SB R\WOL – PARIS 240-SB BA\OL - PARIS 
240-SB BC\CL - PARIS 240-SB BAC\OCL - PARIS 240-SB R\WOL  PARIS 240-SBBA\OL -PARIS 240-SB BC\CL – 
PARIS 240-SB BAC\OCL. 

 

PARIS 240 actuators for swing gates are hydraulic units comprising an electric pump and a hydraulic piston 
which transmits motion to the leaf. 

END USER INSTRUCTION MANUAL 

Содержание PARIS 240-RB R-WOL

Страница 1: ...OXYGEN AUTOMATION TECHNICAL INSTALLATION MANUAL HYDRAULIC GATE OPERATOR PARIS 240MM RB PARIS 240MM SB RB ROUND BRACKET SB SQUARED BRACKET...

Страница 2: ...Equipped automation power net with a double pole switch with contact opening distance equal to or greater than 3mm It is advisable to use a 6A with pole switching 13 Check that upstream of the plant t...

Страница 3: ...ectric pump and a hydraulic piston which transmits motion to the gate The models with a hydraulic block BA BC BAC do not require the installation of electro locks ensuring the mechanical locking of th...

Страница 4: ...astago 240 mm 240 mm 240 mm 240 mm Velocit lineare stelo Speed linear stem Vitesse tige lin aire Velocidad lineal vastago 1 3 cm sec 1 3 cm sec 1 3 cm sec 1 3 cm sec Blocco anta Swing lock Blocage por...

Страница 5: ...o wall and then weld the rear fitting 2 Attach to the pillar with screws and anchors the rear mounting plate and weld on the rear mounting plate Fig 2 B Fix the operator to the rear fig 2 C Release th...

Страница 6: ...e Hinge D share does not allow to contain the A in desidered measure you must make a niche on pillar Fig 2 1 Dimension A must always be greater than the proportion E TABLE REAR SUPPORT FIXING Rod effe...

Страница 7: ...www oxygenautomation com All rights reserved Pag 7 FIXING FRONT SUPPORT PARIS 240MM SB...

Страница 8: ...www oxygenautomation com All rights reserved Pag 8 FIXING FRONT SUPPORT PARIS 240MM RB PARIS 240 RB PARIS 240 SB FIXING ROD COVER...

Страница 9: ...nected with particular attention to the safety devices Deliver to the owner of the User s Guide and explain correct operation and use of the automated system and indicate the potentially dangerous are...

Страница 10: ...nlocked Check valves to force adjustment Check oil level in the tank Check efficiency starting capacitor Check function electronic control unit Gate moves slowly Control adjustment anti crushing syste...

Страница 11: ...intervention of qualified personnel Once you have set the manual mode before restoring normal operation disconnect the power supply Do not modify the components of the automation system Do not attemp...

Страница 12: ...clude safety devices photocells which prevent the leaves from moving when there is an obstacle in the area they protect PARIS 240 actuator comes standard with a hydraulic anti crushing safety device t...

Отзывы: