Rev.0 LEPTON
Service
manual
OXYGEN S.p.A.
27
Figure 11
If you loose or damage the electronic key so that the LEPTON cannot start, you
need to initialize the DRIVE in order to use a new different electronic key. The new key
is supplied directly by OXYGEN.
To install the new key, use the following instructions:
•
Turn OFF the LEPTON;
•
Insert the MASTER KEY (Figure 10) into the connector placed on the left
side of the legshield (Figure 8);
•
Turn ON the LEPTON;
•
The initialization phase is starting so that the message “CODE” will appear
on the dashboard LCD (8 - Figure 11);
•
Let the scooter stay on this state at least for 30 seconds. Now the DRIVE is
initialized;
•
Turn OFF the LEPTON;
•
Take off the MASTER KEY. Insert the new key ;
•
Turn ON the LEPTON. During this phase the DRIVE read the new code of
the key and set the starting connected with the new key.
Figure 8/a shows the device that recognizes the electronic key. The device is
binded to the legshield. It reads the data key and comunicates with the DRIVE.
NOTE : sometimes happens that the substitution key shows a different plastic
cover. This difference does not influence the usual working of the initialization
sequence.