A wiper is fitted that may be remotely controlled to clear water from the viewing window of the
camera.
A version fitted with an LED illuminator is available. It consists of a set of white and infra-red
LEDs that are powered and controlled from within the PTZ unit. The lights are controlled
automatically to provide optimum illumination adjusted to the zoom distance of the camera.
Manual selection of white lighting is available via the control menus.
Specification
Value
Ingress Protection
IP67 (To BS EN 60529)
Housing Construction
Die-cast aluminium
Window
Toughened glass
Housing Finish
Three stage paint system. Finish, powder coat to required
colour. Tested to EN60068-2-52.
Weight (with LED illuminator)
6.9 kg
Weight (without illuminator)
6.6 kg
Dimensions
See Figure 4 & 5
Mounting flange
4 x 10mm diameter
bolt holes on 4” (102mm) PCD
Maximum operating
temperature
60°C (Continuous)
Minimum operating
temperature
-30°C Non-icing conditions
Wind loading
100 mph (no damage), 70 mph fully controlled operation
Wiper
Fitted as standard (integrated control)
Bearings
Ball bearings for pan and tilt
Pan movement
360° continuous
Tilt movement
360° continuous but limited to 180 degrees in software
Housing impact resistance
Tested to EN62262
–
IK10
Vibration resistance
Tested to EN60068-2-6
Shock resistance
Tested to EN60068-2-27
Electromagnetic compatibility
Tested to EN50130-4, EN55032 (Class A)
7.2.
Electrical Features
The PTZ Unit must be connected to an approved Power Supply Unit (PSU) which converts mains
electricity to the 48V DC required to run the PTZ unit. The PSU should be rated for the maximum
power required at all operating temperatures of the PTZ to avoid damage to the PTZ unit or
overloading of the PSU. An EMC suppression unit should be fitted in the power supply lines to
maintain EMC compliance.
Power Specification
Value
Power Supply Voltage
46-50 Volts DC
PTZ Input Power required in varying conditions:
Camera static, no lights, no wiper, tour on.
Camera static, lights on, no wiper, tour on.
Camera zooming, Lights on, Wiper on, Motors full load.
Recommended PSU min output power at max temp.
5-10 Watts
15-22 Watts
96 Watts*
100 watts