Installation
2-3
R
ACK
M
OUNT
I
NSTALLATION
(I
F
APPLICABLE
)
Figure 2–2 Tabletop Clearance Allowance
Rack Mount Installation (If applicable)
The LoaderXpress can be mounted in a standard 19-inch EIA/RETMA rack with a depth of
24 to 30 inches. Units that are purchased as rackmount units are shipped with the top
cover and rack slides installed. Tabletop units may be rackmounted by installation of the
available conversion kit. This section addresses the installation of the top cover, rack slides
and placing the unit in the rack.
NOTE:
The cooling fan at the rear of the drive must not be obstructed when the drive is
installed in the rack. It is advisable to allow a minimum two inches of clearance
behind the rear panel of the module.
Enter
Esca pe
Ready
Us e
Cleaner
Drive
F ault
L oader
Fault
LXL-0013a
Min 2"(5.1cm)