Valves, co systems

“Regumat S-180 WMZ“ / “Regumat M3-180 WMZ“ DN 25

Installation and operating instructions for the specialised installer

EN

Read installation and operating instructions in their
entirety before installing the heat meter!
Installation,  initial  operation,  operation  and
maintenance must only be carried out by qualified
tradesmen!
The installation and operating instructions, as well
as  other  valid  documents  must  remain  with  the
user of the system!

Content

1

General information  . . . . . . . . . . . . . . . . . . . . . 7

2

Safety notes  . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3

Transport, storage and packaging  . . . . . . . . . 8

4

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 8

5

Construction and function . . . . . . . . . . . . . . . . 9

6

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

7

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

8

Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . 12

9

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . 12

10 Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Illustr. 1.1 “Regumat M3-180 WMZ“ 

1 General information

1.1 Information regarding installation and operating

instructions

These installation and operating instructions serve the
qualified installer to install the heat meter connection
set professionally into the product group and to put it
into operation.
Other  valid  documents  –  manuals  of  all  system
components, especially the operating instructions of
the circulation pump and heat meter, as well as valid
technical rules – must be observed.   

1.2 Keeping of documents

These  installation  and  operating  instructions  should
be kept by the user of the system.

1.3 Copyright

The installation and operating instructions are copy-
righted.

1.4 Symbol explanation

Safety  guidelines  are  displayed  by  symbols.  These
guidelines  are  to  be  observed  to  avoid  accidents,
damage to property and malfunctions.

Subject to technical modification without notice.

135605080     12/2016

For an overview of our global presence visit
www.oventrop.com.

DANGER 

indicates 

an

imminent dangerous situation which will lead to death
or  serious  injury  if  the  safety  guidelines  are  not
observed.

WARNING 

indicates 

a

possible dangerous situation which may lead to death or
serious injury if the safety guidelines are not observed.

NOTICE indicates a possible

damage  to  property  which  may  occur  if  the  safety
guidelines are not observed.

CAUTION indicates a possible

dangerous  situation  which  may  lead  to  minor  or
moderate  injury  if  the  safety  guidelines  are  not
observed.

DANGER

NOTICE

!

WARNING

!

CAUTION

!

!

Содержание Regumat M3-180 WMZ

Страница 1: ...lten 1 2 Aufbewahrung der Unterlagen Diese Einbau und Betriebsanleitung ist vom Anlagen betreiber zum sp teren Gebrauch aufzubewahren 1 3 Urheberschutz Die Einbau und Betriebsanleitung ist urheberrech...

Страница 2: ...die Rohrleitungssysteme Durch den Einbau eines W rmemengenz hlers in den Regumaten kann der Energieanteil des Heizungs wassers erfasst werden Jede dar ber hinausgehende und oder andersartige Verwendu...

Страница 3: ...eliefert Die einzelnen Komponenten werden handfest montiert Die Verbindungen sind nach Einbau von Pumpe und W rmemengenz hler nachzuziehen Der Anschlusskasten der Pumpe muss in 9 Uhr Stellung stehen D...

Страница 4: ...inen Fall unter Systemdruck gel st werden Es besteht die Gefahr dass unkontrollierbar hei es Wasser austritt WARNUNG Abb 5 2 Bypasseinstellung Sicherungs schraube 5 4 Stellmotor Regumat M3 Der elektri...

Страница 5: ...turf hler des W rmemengenz hlers mit dem im Lieferumfang des W rmemengenz hlers enthaltenen Montagematerial in den Stopfen einschrauben Abb 5 5 Montage W rmemengenz hler Einbauset Baul nge 110 mm Baul...

Страница 6: ...gumat M3 bleibt unver ndert 5 8 Kennzeichnungen Angabe der CE Kennzeichnung auf der Pumpe CE Kennzeichnung Angaben auf dem Geh use OV Oventrop DN Nennweite 5 7 Einsatz von Hocheffizienzpumpen Die Regu...

Страница 7: ...valid documents manuals of all system components especially the operating instructions of the circulation pump and heat meter as well as valid technical rules must be observed 1 2 Keeping of documents...

Страница 8: ...connection system outside the above applications will be considered as non compliant and misuse Claims of any kind against the manu facturer and or his authorised representatives due to damages caused...

Страница 9: ...hout pump and heat meter The components are supplied loosely connected All connections have to be tightened after installation of the pump and heat meter The connection box of the pump must be in 9 o...

Страница 10: ...ust never be loosened when the system is under pressure There is danger that hot water may escape uncontrollably WARNING Illustr 5 2 Bypass setting Safety screw 5 4 Actuator Regumat M3 The electrical...

Страница 11: ...crew plug M10x1 with O ring into the isolating device Screw flow temperature sensor of the heat meter into the plug by use of the mounting material supplied with the heat meter Illustr 5 5 Installatio...

Страница 12: ...e insulation Red supply blue return A modification of the mixing valve Regumat M3 is not required 5 8 Markings CE marking on the pump CE marking Indications on the body OV Oventrop DN Size 5 7 Use of...

Страница 13: ...es ainsi que les r gles techniques d usage en vigueur sont respecter 1 2 Conservation des documents Cette notice d installation et d utilisation doit tre conserv e par l utilisateur de l installation...

Страница 14: ...ur e en quipant le Regumat d un compteur de calories Tout cart par rapport aux sp cificit s du Regumat est interdit et r put non conforme Les revendications de toute nature l gard du fabricant et ou s...

Страница 15: ...surfaces chauffantes La station de raccordement pour chaudi res est four nie sans circulateur et sans compteur de calories Les composants individuels sont livr s assembl s Apr s le montage du circulat...

Страница 16: ...re desserr e quand le syst me est sous pression De l eau chaude peut s couler AVERTISSEMENT Fig 5 2 R glage bypass Vis de fixation 5 4 Moteur Regumat M3 Le branchement lectrique doit tre effectu selon...

Страница 17: ...ns le dispositif d arr t Visser la sonde de temp rature de d part du comp teur de calories dans le bouchon l aide du mat riel de montage livr avec le compteur de calories Fig 5 5 Assemblage du jeu de...

Страница 18: ...se Regumat M3 reste inchang e 5 8 Marquages Marquage CE sur le circulateur Marquage CE Indications sur le corps OV Oventrop DN Dimension 5 7 Utilisation de circulateurs haut rendement Les groupes de r...

Страница 19: ...professionale Osservare i documenti correlati i manuali d istruzioni di tutti i componenti dell impianto come anche le norme tecniche in vigore 1 2 Conservazione dei documenti Queste istruzioni di mon...

Страница 20: ...alla tubazione risparmiando tempo e spazio Grazie all installazione del contacalorie nei Regumat si pu misurare il consumo di energia per l acqua di riscaldamento E vietato ed considerato scorretto o...

Страница 21: ...I singoli componenti vengono forniti debolmente serrati Dopo l installazione della pompa e del contacalorie stringere a fondo i collega menti La cassetta di connessione della pompa deve essere posizio...

Страница 22: ...SO Fig 5 2 Regolazione bypass Vite di blocco 5 4 Servomotore Regumat M3 L allacciamento elettrico deve essere eseguito se condo le disposizioni di legge AVVERTENZA I gruppi pompa con valvola miscelatr...

Страница 23: ...OR nel dis positivo d intercettazione Avvitare ai tappi della sonda mandata del contaca lorie con il materiale di montaggio compreso nella fornitura del contacalorie Fig 5 5 Montaggio kit d installaz...

Страница 24: ...del marchio CE sulla pompa marchio CE Dati sul corpo OV Oventrop DN larghezza 5 7 Impiego di pompe ad alta efficienza I gruppi premontati Regumat sono adatti per l impiego di pompe ad alta efficienza...

Отзывы: