S-93--E
9. GENERAL SPECIFICATIONS
Item
Description
Model
TF0
TF00
TF0
TF00
TF00
Nominal Size
mm
0mm
mm
0mm
0mm
Acceptable Fluid
Compressed air and nitrogen
Flow Range
※
0 to 00 L/min
(
normal
)
to 00L/min
(
normal
)
3 to 00L/min
(
normal
)
to 000L/min
(
normal
)
3 to 000L/min
(
normal
)
Fluid Temperature
0 to 0
°
C
Ambient Temperature
0 to 0
°
C
Pressure Range
0 to 0.MPa
Major Parts
Materials
Monitor body: PBT (Polybutylene Terephtalate)
Monitor body: A0 (Machined, anodized)
Sensor: SUS3
Display: Mixed resin consiting of PC (Polycarbonate) and PBT (polybuthylene terephthalate)
Transmitter case: PBT (Polybutylene Terephtalate)
O-rings: Viton
Connection Rating
Rc/ (female)
Rc3/ (female)
Rc (female)
Rc
・
/ (female)
Rc (female)
Connector
Material
ADC
(Aluminum die cast,
Alodine (trivalent))
A0 (Aluminum machined and anodized)
Display
-segment -digit LCD (with backlight and unit indicator). The display is rotatable in 90
°
steps.
• Instant flowrate (m
3
/h(normal), (L/min(normal))
• Resettable total flow, accumulated total flow (m
3
(normal))
• Yen conversion (instant flowrate, accumulated total, resettable total)
NOTE: In the Yen converted mode, the unit of figure is "Yen".
LED x places (Lights up in an alarmed condition).
Output
Flow pulse (compensation pulse, open collector output)
(Pulse width adjustable from to 0 msec)
Alarm ( points, open collector output)
Flowrate analog to 0mA, Max. load resistance 00
Ω
Alarm
• independent set points can be chosen (settings, hysteresis, or high/low alarms.)
• The lowest limit of alarm can be set up. (Alarm can be cleared at around 0 flow.)
Pressure Loss
0kPa max. (flowing at the max. flowrate above 0.3MPa)
Response
Time constant . sec. max.
Power
VDC
±
0%, Max. 00 mA
Cable
Refer to Section . Wiring Diagram.
Physical Orientation
Horizontal or vertical
Protection Grade
Non-explosionproof, indoor use, IP
NOTES:
※
. Reading in terms of "Normal" refers to the conversion value at 0
°
C and atm. As the
maximum flowrate could camage the sensor, it is limited by the pressure inside the tubing
system. Refer to Section . Maximum Service Flowrate.
※
. You can select to optional output points. (For the combination, refet to the product code.)
● Accuracy (all meter sizes)
Flowrate below 40% of full scale
Flowrate 40% or more of full scale
Reproducibility
±
0.% of full scale or better
±
% of reading or better
Linearity
±
% of full scale or better
±
% of reading or better
Pressure characteristics
±
0.% of full scale/0. MPa or better
±
0.3%/0. MPa of reading or better
Temperature characteristics
±
0.%/
°
C of full scale
±
0.%/
°
C of reading
10. APPLICABLE STANDARDS
Applicable EU Directive
EMC Directive: 0/30/EU
RoHS Directive: 0//EU
Applicable EN standards, etc.
EMC Directive: EN3-: 03 Class A
RoHS Directive: EN0: 0
※