S-93--E
0
1: SUP (power +)
4: Flow pulse output
3: COM (power-)
GND
Shielded wire
Connect the shielded wire to GND.
BRN: SUP (power +)
WHT: Alarm 1 output
YEL: Flow pulse output
GRN: COM (power -)
max.
30VDC,
20mADC
max.
30VDC,
20mADC
24VDC±10%
BRN: SUP (power +)
2: Alarm 1 output
Connector terminal
1
3
4
2
WHT: Alarm 1 output
BLK: Flow pulse output
BLU: COM (power -)
max.
30VDC,
20mADC
max.
30VDC,
20mADC
24VDC±10%
●
Cable (OMRON)
●
Cable (OVAL)
Model:
XS2F-D42□-□80-F
Note: For cables, refer to the following figures.
• When product code "Output terminal" is [2] or [4], OVAL cable is supplied.
• When product code "Output terminal" is [3] or [5], cable must be prepared by the customer.
In this case, OMRON cable is recommended.
25 cm
3m
6. WIRING CONNECTIONS
6.1 Wiring Specifications
Table .
Item
Description
Transmission cable
(Depends on your
specification).
The following cables are supplied depending on the th digit of the product code.
[]:
-conductor shielded cable of 3 meters long (O.D.: .3mm) ... Fixed to this
unit.
[][]: -conductor shielded cable of 3 meters long (O.D.: .3mm, -pin connector is
provided at the one side of the cable) ... Supplied with this unit.
Alarm output
Open collector output
Allowable current: 0mADC
Max. voltage impression: 30VDC
Flow pulse output
Open collector output
Allowable current: 0mADC
Max. voltage impression: 30VDC
Flow analog output to 0mA corresponding to 0 to F.S.
Supply Voltage
VDC
±
0
%
6.2 Wiring Diagram
NOTE: For output terminal types and styles, see "Explanation of Output Terminal Types" below NOTES in
Sec. .
CAUTION:
1. Use extra care about the polarities of power source.
2. Do not fail to earth ground the shielded wire to GND.
(1) Flow pulse single alarm point specifications (Fig. 6.1)
●
Connector terminal
●
Connector via interconnect cable
Fig. .