S-93--E
To view parameters of interest, hold the "MODE" button depressed for seconds at the flow variables
window to show ALA window. The diagram below will lead you the rest of the way using the "MODE" and
"RESET" buttons until the parameter desired appears.
("XXX" in each box at left represents a numerical value of the variable).
NOTES: . See Sec. .3 for acceptable parameter setting
range and factory set defaults.
.
※
: Models not provided with an analog
output do not show these menu items.
Basic data menu
Press MODE for sec.
Yen conversion
factor
Full scale flowrate
All figure places
illuminated
Zeroing
Damping time
Press MODE .
Dummy output
Pulse weight
Pulse ON width
Cutoff
Analog trim (mA)
Analog trim (0mA)
Menu item
Description
Yen
conversion
factor
A parameter to perform conversion to obtain Yen equivalent. Yen
equivalent represents the cost per unit flow of m
3
(normal) of me-
tered process fluid.
Reads in Yen/m
3
(normal).
When set to "0", Yen conversion does not take place.
Pulse weight
Unit flowrate per single output pulse.
Reads in L (normal).
To change the setpoint, be sure to meet the following conditions. Un-
less these conditions are satisfied, proper pulse output is not pro-
duced.
Max. service flowrate [L/min (normal)] / pulse weight
[L(normal)] x (pulse "ON" [msec] + ) / 0 < 000
Pulse ON
width
Output pulse width.
Reads in msec.
Unless the same conditions as those of pulse weight are satisfied,
proper pulse output is not produced.
Cutoff
Instantaneous flowrate cutoff setpoint.
Any flow below this flowrate reads "0".
Reads in L/min (normal).
Dummy
output
A 0Hz pulse output is available irrespective of the flowrate curently
in measurement. You can use this feature in verifying the connections
with other system, or for other purpose. (For the procedure of produc-
ing dummy output, see Sec. . "Dummy Pulse Output".)
Analog Full
scale flowrate
※
Flowrate at analog output full scale (0mA).
Analog
Damping time
※
Sets damping time for analog output. (Due to inherent circuit proper-
ties, approx. sec time const. exists besides software setting.)
Reads in sec.
Analog trim
(mA)
※
Trims analog output of mA.
(For details, see Sec. . "Analog Output Trim".)
Analog trim
(0mA)
※
Trims analog output of 0mA.
(For details, see Sec. . "Analog Output Trim".)
Zeroing
Adjusts the zero baseline. The product is shipped after calibration in
the factory. Normally, the product does not require Zero baseline ad-
justment.
To adjust, press ahd hold the "MODE" button for more than sec-
onds while pressing the "RESET" button in this mode.
Backlight
setting
You can select any one of four backlight activation modes.
On: Illuminated full time, EC: Illuminated full time at the half level of
illumination at On time, OF: Always unlit, SL: Illumination darkened to
half approx. 0 sec. after completing button operation.
All figure
places
illuminated
This feature is useful in testing the illumination of LCD display and
alarm LED indicator lamps.
Illuminates all LCDs and alarm LEDs.
(Alarm output appears as usual.)
X
.
X
.
X
.
X
.
X
.
X
.
X
X
.
X
.
X
.
X
.
X
.
X
X
.
X
.
X
X
.
X
.
X
.
X
.
X
.
X
X
.
X
.
X
.
X
X
.
X
.
X
.
X
.
X
X
.
X
.
X
.
X
.
X
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
Press MODE .
X
.
X
.
X
....................
....................
....................
....................
....................
....................
....................
....................
....................
....................
....................
....................
Press MODE .
Backlight setting
X
.
X