D-582-3-E
8
Fig. .0
Option
Fig.A
Fig.B
Fig.C
Retract
Handwheel
Screw Axis
No.
Part Name
Q'ty Remarks
30
Cover
3
Adaptor A
30
Shaft Retaining Bolt
2
M2
3
Hex Nut A
2
M2
Connecting Stud
2
Hex Bolt
3
M
5
Hex Nut
2
M
6.9 Hottap Type Drive Unit Removal
The drive unit (retractable assembly including the handwheel and screw axis) can be separated. It is
beneficial in applications where line vibration is great, or where a single drive unit is shared by multiple
flowmeters.
①
Installing the shaft fitting bolts [Fig. A]
Secure the adaptor A to the cover with shaft fitting bolts and hex nuts A. (This prevents the shaft from
being forced upward under line pressure.)
②
Separating the shaft from its connection [Fig. B]
Taking off two hex nuts, turn the handwheel to extract the connecting studs from the adaptor A.
③
Removing the drive unit [Fig. C]
Taking off three hex bolts, remove the drive unit. Exercise care not to bump against the preamplifier or
other components.
Drive unit removal procedure
Drive unit installation is the reverse of the removal instructions.