OPERATING THE FIRE PIT

PURGE GAS LINES

Upon completing the gas line connection, a small 

amount of air will be in the lines. When the first lighting 

the burner, it will take a few seconds for the lines to 

purge themselves of this air. 

Once the purging is complete, the burner will light 

and operate as indicated in the instruction manual. 

Subsequent lighting of the appliance will not require 

purging unless the gas supply has been disconnected. 

Inspect the gas hose before each use of the fire pit. If 

the hose shows evidence of excessive abrasion or wear 

or if the hose is damaged, it must be replaced before 

using the fire pit. Inspect the burner before each use of 

the appliance. If there is any evidence that the burner 

is damaged, it must replaced before operating. Upon 

completing the gas line connection, a small amount of 

air will be in the lines. When first lighting the burner, it 

will take a few minutes for the lines to purge themselves 

of this air. Subsequent lighting of the appliance will not 

require such purging. Never allow the ON / OFF valve to 

remain in the open position without placing a burning 

match on top of the burner FIRST! 

You must have clear and easy access to the ON 

/ OFF valve AFTER the appliance is installed and 

connected to the gas supply in order to safely turn of 

the burner. Make sure the burner is in place prior to 

using the appliance. If the burner is damaged, install a 

replacement burner as specified by the manufacturer. 

FOR YOUR SAFETY, READ BEFORE LIGHTING. 

 

õ

Before operating smell all around the appliance 

area for gas odors and next to the floor because some 

gases are heavier then air and will settle on the floor. 

 

õ

Use only your hand to turn the manual gas control 

valve. Never use tools. If the valve will not turn by 

hand, do not try to repair it. Call a qualified service 

technician. Force or attempted repair may result in a 

fire or explosion.

LIGHTING INSTRUCTIONS 

1. Turn the ON/OFF valve located on the side of fire pit 

 

    completely to the ON position. 

2. Make sure fuel supply (LP or NG) is properly 

 

    connected and turned on at the source. This will be 

 

    either the LP tank or the NG valve. 

3. When you hear gas flowing, using either a long stem 

 

    wooden match or a butane fireplace lighter, place the 

 

    flame near the burner. 

4. If the burner does not light, does not stay lit, or the 

 

    flame is very low, shut off all gas supply and wait 

 

    five minutes to allow all gas fumes to clear. Start again 

 

    from step 1, making sure all gas valves are completely 

 

    opened. 

TURNING OFF GAS 

For NG units: Turn the ON/OFF valve to the OFF position 

at the unit for natural gas unit, then close the valve at 

the NG source. 

For propane units: Turn the ON/OFF valve to the OFF 

position at the unit and then close the valve on the 

propane tank. 

Note:

The propane regulator in this appliance is equipped 

with a low flow protection device. Unless the propane 

cylinder valve is opened before the valve, the gas flow 

will be reduced resulting in a very small flame. To reset 

this device, shut off the valve, disconnect the hose 

from the cylinder to relieve the pressure, then close the 

propane cylinder valve.

DO NOT USE SOLID FUEL, SUCH AS WOOD OR CHARCOAL, IN GAS FUELED FIRE PITS. 

  WARNING

SIENNA

 | FIRE PIT

Содержание OPT-RF37

Страница 1: ...PHONE 909 460 5579 THEOUTDOORPLUS COM 235 E MAIN ST ONTARIO CA 91761 1 SIENNA 37 FIRE PIT OPT RF37 ...

Страница 2: ...12 OPERATING THE FIRE PIT 13 PURGE GAS LINES 13 FOR YOUR SAFETY READ BEFORE LIGHTING 13 LIGHTING INSTRUCTIONS 13 TURNING OFF GAS 13 GAS CONVERSION 14 FOR LIQUID PROPANE 14 FOR NATURAL GAS 14 CLEANING MAINTENANCE STORAGE 15 CLEANING 15 MAINTENANCE 15 STORAGE 15 REPLACEMENT PARTS 16 ONE YEAR LIMITED WARRANTY 16 CLEARANCE FROM COMBUSTIBLES 17 INSTALLATION 17 FLOORING 17 SERVICE 17 Sienna an earth sha...

Страница 3: ... and immediately call your gas supplier or fire department Ne pas entreposer ne utilizer de l essence ni d autres vapuers ou liquids inflammables dans le voisinage de l appareil ne de tout autre appareil Une bouteille de propane qui n est pas raccordee en vue de son utilisation ne doit pas etre entreposee dans le voisiange de cet appariel ou de tout autre appreil POUR USAGE A L EXTERIEUR SEULEMENT...

Страница 4: ...ire pit for cooking Do not heat any unopened glass or metal container of food in the fire pit Pressure may build up and cause the container to burst possibly resulting in serious personal injury or damage to the fire pit Never use the fire pit in windy conditions If used in a consistently windy area a windbreak will be required Always adhere to the specified clearances listed in this manual Never ...

Страница 5: ... could cause burns Do not reach over your fire pit when hot or in use Do not store items of interest to children around or below the fire pit Never allow children to sit or stand on any part of the fire pit In the event that a burner goes out turn burner knobs to the full OFF position and let the gas dissipate Do not attempt to use the fire pit until the gas has had time to dissipate Keep all elec...

Страница 6: ......

Страница 7: ...inder used must include a collar to protect the cylinder valve Filler Valve If you do not have an updated filler valve on your existing propane tank you will need to purchase one at your local hardware store as you will not be allowed to refill the tank at any filling station PHONE 909 460 5579 THEOUTDOORPLUS COM 235E MAIN ST ONTARIO CA 91761 NATURAL GAS Ensure that the service supplying the fire ...

Страница 8: ...ooms as well as solvents cleaning fluids and gasoline Do not block the vents located near the base of your fire pit as gas may build up in case of leak and cause serious damage Do not locate appliance where it can get excessively wet Do not use this appliance if any part has been underwater Immediately call a qualified service technician to inspect the unit and to replace any part of the control s...

Страница 9: ...e shifted during transit Before you set the burner plate in place check the air mix fixture connected under the burner plate The air mix fixture has six holes that regulate the amount of air that goes to the burner When the nut is rotated forward to cover the six holes the burner is configured for liquid propane Make sure the air mix appears the way it does in Figure C Perform a leak test before y...

Страница 10: ... the burner plate in place make sure the air mix fixture is connected undereath the pan max 6 away from an open flame The air mix fixture is required for liquid propane but not for natural gas See Step 2 Make sure the flex hose is connected to the burner as shown in Figure E Perform a leak test before you replace the burner plate See Step 3 Connect to the gas source LOCATING THE GAS LINE Make sure...

Страница 11: ...part water 2 Make sure all the control knobs are in the OFF position 3 Turn on the gas 4 Apply the leak testing solution by spraying it on joints of the gas delivery system Blowing bubbles in the soap solution indicates that a leak is present 5 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer Do not attempt to repair ...

Страница 12: ...ct the operation of the fire pit in any way You can place the filler material on the burner but no higher than 1 thick above the burner Excessive filler material may impede gas flow and cause gas build up and potentially cause an explosion FIGURE K GAS SPECIFICATIONS NG TO LP PARTS LP TO NG PARTS PRESSURE NATURAL GAS PROPANE MINIMUM 3 5 W C 8 0 W C NOMINAL 7 0 W C 11 0 W C MAXIMUM 1 2 psi 14 0 W C...

Страница 13: ... SAFETY READ BEFORE LIGHTING õ õ Before operating smell all around the appliance area for gas odors and next to the floor because some gases are heavier then air and will settle on the floor õ õ Use only your hand to turn the manual gas control valve Never use tools If the valve will not turn by hand do not try to repair it Call a qualified service technician Force or attempted repair may result i...

Страница 14: ...vert your fire pit to use either liquid propane or natural gas any time you wish Before you begin read the gas requirement on page page 4 Fire pit owners who convert from liquid propane need to have a proper natural gas line installed preferably by a licensed contractor Make sure the fire pit is cool and all gas lines have been shut off Remove the decorative stone from the fire pit Lift the burner...

Страница 15: ...s not cracked or damaged in any way All natural gas hook ups should be serviced and inspected only by qualified installers only Spiders and other insects can nest in the burners and block the gas and airflow to the burner ports This creates a dangerous condition that can result in a fire from behind the valve panel Inspect and clean the burners periodically Any guard or other protective device rem...

Страница 16: ...repair of a covered item is not feasible we reserve the right to replace the defective merchandise with merchandise equal in value to the original purchase price Warranty repair or replacement are the sole discretion of The Outdoor Plus and this warranty does not cover costs therein including but not limited to freight removal re installation etc There will be no charge for parts on a covered item...

Страница 17: ...ion in gas piping FLOORING All fire pits and fire features must be installed on non combustible flooring If the fire feature is installed on a combustible floor such as wood decking a non combustible floor paneling MUST be properly installed underneath the fire unit SERVICE We suggest that our products be serviced by a professional certified in the US by the National Fireplace Institute NFI as NFI...

Отзывы: