GAS REQUIREMENTS
LIQUID PROPANE
Your Outdoor Plus fire pit is not provided with a
propane tank. You will need to provide one. Use these
specification for purchasing your propane tank:
SPECIFICATIONS
The 20 lb propane gas supply cylinder is constructed
and marked in accordance with the specifications
for propane gas cylinders as required by the U.S.
Department of Transportation (DOT), Specifications for
LP-Gas Cylinders, or the Standard for Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods and
Commission, CAN/CSA B339, as applicable.
Manifold Pressure:
For plumbed-in liquid propane
installation, use a regulator.
Supply Pressure:
Natural Gas:
Minimum 3.5” W.C. Maximum 7.0” W.C.
Liquid Propane:
Minimum 8.0” W.C. Maximum 11.0” W.C.
Pressure Regulator:
The unit must be used with the
supplied gas pressure regulator and hose assembly.
The regulator will control and maintain a uniform gas
pressure in the manifold. The burner orifice has been
sized for the gas pressure delivered by the regulator.
Replacement pressure regulator and hose assemblies
must be those specified in this manual.
Cylinder Specification:
Any propane gas supply
cylinder used with this fire pit must be approximately 12
inches in diameter and 18 inches high. The maximum
fuel capacity is 20 lbs. of propane, or 5 gallons. Full
cylinder weight should be approximately 38 lbs. (43.7
lbs. nominal water capacity.) Always use the cylinder
dust cap on the cylinder valve outlet during transport
and when the cylinder is not connected to the fire pit.
The 20 lb propane gas cylinder used must include a
collar to protect the cylinder valve.
Filler Valve:
If you do not have an updated filler valve
on your existing propane tank, you will need to purchase
one at your local hardware store, as you will not be
allowed to refill the tank at any filling station.
PHONE: (909) 460-5579 | THEOUTDOORPLUS.COM | 235 E MAIN ST. ONTARIO, CA 91761
NATURAL GAS
Ensure that the service supplying the fire pit is fitted
with a conveniently positioned shut off valve with easy
access. The shut off valve MUST NOT be inside the
appliance!
REQUIREMENTS
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the fire pit
is manufactured for.
The installation of this appliance must conform with
local codes or, in the absence of local codes, to the
National Fuel Gas Code, ANSI Z223.1, NFPA 54; National
Fuel Gas Code; Natural Gas and Propane Installation
Code, CSA B149.1; or Propane Storage and Handling
Code, CSA B146.2, as applicable. Natural gas connection
must be performed by a licensed contractor or local gas
company representative.
Ensure that the service supplying the fire pit is fitted
with a conveniently positioned shut off valve with easy
access.
PRESSURE TESTING
If this fire pit is installed with a fixed fuel piping
system and equipped with an appliance gas
pressure regulator, the fire pit and its individual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing
of the system at test pressures in excess of 1/2 psi
The fire pit must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psi