12
GAS REQUIREMENTS
•
Use propane or butane gas only.
•
The pressure regulator and hose assembly to be used must conform to local
standard codes.
•
The installation must conform to local codes, or in the absence of local codes,
with the standard for the storage and handling of liquid petroleum gases.
•
A dented, rusted or damaged propane tank may be hazardous and should be
checked by your tank supplier. Never use a propane tank with a damaged valve
connection.
•
The propane tank must be arranged to provide for vapor withdrawal from the
operating cylinder.
•
Never connect an unregulated propane tank to the heater.
CLEANING AND CARE
•
Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with
cleaners that are combustible or corrosive.
•
Remove debris from the burner to keep it clean and safe for use.
•
Cover the burner unit with the optional protective cover when the heater is not in
use.
OPERATION AND STORAGE
TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the variable control knob to PILOT position(counter-clockwise 90°).
3. Press down the variable control knob and hold for 90 seconds. While holding
down the variable control knob, press the igniter button several times until the pilot
flame lights. Release the variable control knob after the pilot flame lights.
Note:
•
If a new tank has just been connected, please allow at least one minute for the
air in the gas pipeline to purge out through the pilot hole.
•
When lighting the pilot flame make sure that the variable control knob is
continuously pressed down while pressing the igniter button. Variable control
knob can be released after the pilot flame lights.
•
Pilot flame can be watched and checked from the small round window with
sliding lid located at the bottom of the flame screen(to the left or right side of the
controller)
•
If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights, turn the variable control knob to maximum position
and leave it there for 5 minutes or more before turning the knob to desired
temperature position.