background image

10 

CAUTION

PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE 

OPERATION.

• 

Do not use the patio heater for indoors, as it may cause personal injury or 

property    damage.

• 

This outdoor heater is not intended to be installed on recreational vehicles and/or 

boats.

• 

Installation and repair should be done by a qualified service person.

• 

Improper installation, adjustment, alteration can cause personal injury or 

property damage.

• 

Do not attempt to alter the unit in any manner.

• 

Never replace or substitute the regulator with any regulator other than the 

factory-suggested replacement.

• 

Do not store or use gasoline or other flammable vapors or liquids in the heater 

unit.

• 

The whole gas system, hose, regulator, pilot or burner should be inspected for 

leaks or damage before use, and at least annually by a qualified service person.

• 

All leak tests should be done with a soap solution. Never use an open flame to 

check for leaks.

• 

Do not use the heater until all connections have been leak tested.

• 

Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve 

OFF. If leak is at Hose/Regulator connection: tighten connection and perform 

another leak test. If bubbles continue appearing should be returned to hose’s 

place of purchase. If leak is at Regulator/Cylinder Valve connection: disconnect, 

reconnect, and perform another leak check. If you continue to see bubbles after 

several attempts, cylinder valve is defective and should be returned to cylinder’s 

place of purchase.

• 

Do not transport heater while it’s operating.

• 

Do not move the heater after it has been turned off until the temperature has 

cooled down.

• 

Keep the ventilation opening of the cylinder enclosure free and clear of debris.

• 

Do not paint the radiant screen, control panel or top canopy reflector.

• 

Control compartment, burner and circulation air passageways of the heater must 

be kept clean. Frequent cleaning may be required as necessary.

• 

The LP tank should be turned off when the heater is not in use.

• 

Check the heater immediately if any of the following occurs:

- The heater does not reach temperature.

- The burner makes popping noise during use (a slight noise is normal when the 

burner is extinguished).

- Smell of gas in conjunction with extreme yellow tipping of the burner flames.

• 

The LP regulator/hose assembly must be located out of pathways where people 

may trip over it or in area where the hose will not be subject to accidental damage.

• 

Any guard or other protective device removed for servicing the heater must be 

replaced before operating the heater.

Содержание OUT370609/PH100T

Страница 1: ...l gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier or your fire Department FOR YOUR SAFETY 1 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 2 An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance OUT370610 PH200T ...

Страница 2: ...iance must be installed and the gas cylinder stored in accordance with the regulations in force Do not obstruct the ventilation holes of the cylinder housing Do not move the appliance when in operation Shut off the valve at the gas cylinder or the regulator before moving the appliance The tubing or the flexible hose must be changed within the prescribed intervals Use only the type of gas and the t...

Страница 3: ...ts 9 Cup Nuts M6 mm 9 Small Screws M6 x 10 mm 9 Small Flat Washers Ø 6 mm for Reflector Assembly 6 Large Bolts and Flange Nuts M6 for Support Legs Main Pole Assembly 3 Medium Bolts M8 x 16 mm for Support Legs Stand Assembly 3 Reflector Spacers and Wing Nuts 9 Large Flat Washers for Reflector and burner Assembly 3 pcs ground fixer 6 pcs M6 x 10 mm ground fixer bolts nuts Quantity varies according t...

Страница 4: ...4 PARTS Quantity varies according to model purchased Specifications subject to change without prior notice 813 mm 460 mm 2222 mm 2003 mm 765 mm Table ...

Страница 5: ...on carefully before assembly 1 2 1 1 Put the 3 pcs post brackets on each position on the base as shown in the picture 1 2 Use 3 Medium Bolts M8x16 to join the post brackets and stand 2 1 Put the post on the top of 3 pcs post brackets 2 2 Use 6 Large Bolts and Flange Nuts M6 to connect the post to the 3 pcs post brackets Tighten the bolts and nuts Bolt Stand Square metal support Bolt Post Nut ...

Страница 6: ...ide fastening nut down the pole with the rounded side faced downwards 4 2 Next slide the tightening spacer down the pole with the smaller side facing downwards Put the table on the pole with the metallic side facing up Tank housing Fastening nut Table Tightening spacer ...

Страница 7: ... inserting it through the middle of the table on the pole Thread the tightening spacer on the bottom of the table counterclockwise onto the screw coupler 5 2 Tighten securely to hold the table to the screw coupler Thread the fastening nut counterclockwise Tighten securely to lock in place Loosen the fastening nut to adjust the position of the table on the pole Screw Coupler Bolt ...

Страница 8: ...hers and 3 pcs Wing Nuts 7 1 Check whether the connection of vertical post and burner are assembled according to instructions and all bolts and nuts are tightened 7 2 Put 6 pcs Large Flat Washers on 3 Reflector Spacers Reflector Spacer Reflector Wing nut ...

Страница 9: ...tness check must be performed at the installation site due to possible mishandling in shipment or excessive pressure being applied to the heater Make a soap solution of one part liquid detergent and one part water The soap solution can be applied with a spray bottle brush or rag Soap bubbles will appear in case of a leak The heater must be checked with a full cylinder Make sure the safety control ...

Страница 10: ...If bubbles continue appearing should be returned to hose s place of purchase If leak is at Regulator Cylinder Valve connection disconnect reconnect and perform another leak check If you continue to see bubbles after several attempts cylinder valve is defective and should be returned to cylinder s place of purchase Do not transport heater while it s operating Do not move the heater after it has bee...

Страница 11: ...s For connection of hose and regulator and connection of regulator and hose please refer to photo showed above Remove plastic wrap from any part before lighting Never cover a heater until it has completely cooled If you have any queries regarding these instructions contact your local dealer To change the gas cylinder in a amply ventilated area away from any ignition source candle cigarettes other ...

Страница 12: ... Turn on the valve on the gas supply cylinder completely 2 Press and turn the variable control knob to PILOT position counter clockwise 90 3 Press down the variable control knob and hold for 90 seconds While holding down the variable control knob press the igniter button several times until the pilot flame lights Release the variable control knob after the pilot flame lights Note If a new tank has...

Страница 13: ...linder after use or in case of a disturbance 2 Remove the pressure controller and the hose 3 Check the tightness of the gas valve and for damage If you suspect a damage have it changed by your gas dealer 4 Never store liquid gas cylinder in a sub terrain or at places without adequate air ventilation Variable control knob Igniter OFF the heater stop work HI maximum temperature position LO minimum t...

Страница 14: ...th the requirements of EN 16436 1 2014 Read the intructions before installation and use Keep the instructions for future reference APPLIANCE CATEGORY TYPES OF GAS Butane Propane GAS PRESSURE 28 30mbar 37 mbar 30 mbar 50mbar 37mbar 30mbar 37 mbar 30 mbar 50mbar 37mbar Butane propane or their mixtures Butane propane or their mixtures Butane propane or their mixtures OUTLET PRESSURE OF REGULATOR 3 28...

Страница 15: ...ea Loose connections Tighten connections Thermocouple bad Replace thermocouple Gas leak in line Check connections Lack of fuel pressure Tank near empty Refill LPG tank Burner will not light Pressure is low Tank near empty Refill LPG tank Opening blocked Remove and clean Control not ON Turn valve to ON Thermocouple bad Replace thermocouple Pilot light assembly bent Place pilot properly Not in corre...

Страница 16: ...tor Fat fires are not covered under warranty Any warrany guarantee claims shall be rendered void in the event of improper use of the heater or the use of non approved fuels discolouration rusting or slight deformation of parts exposed directly to the flames burner do not impair the function of the heater and do not form a basis for any claims This warranty is offered as an extra benefit and is in ...