![otometrics madsen itera ii Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/otometrics/madsen-itera-ii/madsen-itera-ii_reference-manual_1658678097.webp)
20 WARBLE
FREQUENC-
Y
1 Hz to 20 Hz
21 SELECT
AC FREQ.
Here you can select (ON) or cancel (OFF) the frequencies to be included for automatically changing fre-
quencies when you store AC thresholds.
The frequencies are selected using the
FREQUENCY
selector.
ON/OFF is selected using the
right LEVEL
selector.
Note
•
This setting does not influence the
Frequency
knob, and accordingly, all frequencies (includ-
ing inter-octave frequencies) are available when you use the
Frequency
knob.
However, if the frequency 125 Hz is not included in the SELECT AC FREQ. setting, then it will not be
included when you use the
Frequency
knob.
22 SELECT
BC FREQ.
Here you can select (ON) or cancel (OFF) the frequencies to be included for automatically changing fre-
quencies when you store BC thresholds.
The frequencies are selected using the
FREQUENCY
selector.
ON/OFF is selected using the
right LEVEL
selector.
Note
•
This setting does not influence the
Frequency
knob , and accordingly, all frequencies (includ-
ing inter-octave frequencies) are available when you use the
Frequency
knob.
23 SIGNAL
UNIT
•
HL
•
SPL
LED-FLASH
If SPL is selected, the dB button will flash to indicate that the display is showing SPL values and not
HL values.
24 MIC
INPUT
SENSE
Selection of microphone input sensitivity (MIC LED is lit).
If you press and hold
MIC
, you can adjust the left microphone with the
left LEVEL
selector and the right
microphone with the
right LEVEL
selector.
If you turn the
right LEVEL
selector
without
pressing
MIC
, both right and left microphones are adjusted
and the display shows an average of the two.
25 CD
INPUT
SENSE
Selection of CD/Tape input sensitivity (CD LED is lit).
If you press and hold
CD
, you can adjust the left input with the
left LEVEL
selector and the right input
with the
right LEVEL
selector.
If you turn the
right LEVEL
selector
without
pressing
CD
, both right and left inputs are adjusted and the
display shows an average value.
Otometrics - MADSEN Itera II
97
10 Setup of parameters
Содержание madsen itera ii
Страница 1: ...MADSEN Itera II Reference Manual Doc No 7 50 0860 EN 26 Part No 7 50 08600 EN ...
Страница 10: ...1 Introduction to MADSEN Itera II 10 Otometrics MADSEN Itera II ...
Страница 52: ...4 Navigating in the OTOsuiteAudiometry Module 52 Otometrics MADSEN Itera II ...
Страница 60: ...5 Preparing for testing 60 Otometrics MADSEN Itera II ...
Страница 68: ...6 Tone testing 68 Otometrics MADSEN Itera II ...
Страница 74: ...7 Speech testing 74 Otometrics MADSEN Itera II ...
Страница 86: ...9 Managing Data and Results 86 Otometrics MADSEN Itera II ...
Страница 110: ...15 Maximum non destructive voltage 110 Otometrics MADSEN Itera II ...
Страница 118: ...18 Standards and safety 118 Otometrics MADSEN Itera II ...