One Stop Systems
4U Pro 16 Slot
30
9
Applying Power Correctly
9.1
Connecting to electrical outlet
It is highly recommended using a power surge to protect your gear against random power spike damage. This product is provided with a power
supply that
automatically adjusts to input voltages between 100 to 240 Vac
. A U.S. and Canadian 125V or 250V power supply cord is provided
with this product. If you are using a 250V power cord, you would need to connect that to a PDU (power distribution unit). You can buy the PDU
on any online electronic stores. OSS does not sell the PDU.
9.2
Connect Power Cords
Use the power cord supplied with the unit, connect the power cord to the back of the power supply
. Ensure that the system’s power supply
unit is fully secured before connecting the power cord. You should have either the 125v or the 250v power cord. If you only have the 125V
power cord and you require the 250V power cord please contact our Sales Team (
) to place an order.
Power Cord Voltage Table
Power Cord
PSU Watt
Voltage
AMPS
Hz
125V
1000W
100-127V
12-9.5A
50-60Hz
250V
1800W
200-220V
10-9.5A
50-60Hz
250V
1980W
220-230v
10-9.8A
50-60Hz
250V
2000W
230-240V
10-9.8A
50-60Hz
When using 115-125V power cord, the output power is limited (1000W)
Plug in the power cords to the power supplies, the entire unit will power UP.
•
Power Supplies are ON
•
All fans are activated
•
Backplanes are ON