Plan Wiring

Pump 

flow

2-port valve

(supplied)

Zone valve

(not supplied)

Automatic 
bypass

Radiators/

UFH

Heat pump

Piping 
Diagram

Zone Valve (DHW)

 

(supplied)

1 2

2

3

1

T6360B

3

5

7

3

G/Y

L N E 4

G    Br   B

l

    O

L N E

L N E

Pump

1  2  3

2 3

2 3

2

2

3

1

V4043H

OSO 

Cylinder 

Thermostat 

(supplied)

 

Wired as 

high limit stat

Isolated Mains

 

Supply From 

Fused Spur 

Zone Valve (Htg)

 

(not supplied)

Room

 

thermostat

L  N E

6

9

2

3

1

V4043H

G  Br  B1   O    

G/Y

4

8

10

Wiring 

with Heat pump differential controller

1

 

2

 

Thermistor

Thermistor wire 
Connected to 

Heat Pump

 control 

system

1 2

2

3

1

T6360B

3

5

7

3

G/Y

L N E 4

G    Br  

  

B

l

    O

L N E

L N E

Heat Pump

Pump

1  2  3

2 3

2 3

2

2

3

1

V4043H

OSO 

Cylinder

 

Thermostat

 

(supplied)

Isolated Mains

 

Supply From 

Fused Spur 

Zone Valve (Htg)

 

(not supplied)

Room

 

thermostat

L  N E

6

9

2

3

1

V4043H

G  Br

   

B1   O    

G/Y

4

8

10

Wiring for Standard Heat pump

1

 

2

 

Zone Valve (DHW)

 

(supplied)

OSO 

Delta HP VIP

 cylinders

 

can 

be fitted  with  all  types of boilers.  

Standard 

Heat pumps 

operate 

using room  and cylinder 

thermostats. Please follow  upper 

diagram: 

‘Wiring for Standard 

Heat Pump

’. 

Thermistor controlled 

Heat 

Pumps

 

Many popular 

Heat 

Pumps

 now use a thermistor 

principle. A thermistor 

temperature  sensor is  supplied 

with  the 

Heat  Pump

to attach  to 

the cylinder. Temperature 

information is relayed back to the 

Heat Pump

 control system. 

A Pocket is provided

 (see below

 

to secure the sensor on the 

Delta 

HP VIP

 cylinder. 

The probe is run 

through a channel from base of 

cylinder to the immersion housing

 

and housed there in a pocket. The 

thermistor cable should be 

secured using the supplied 

clamps in the bottom opening of 

the channel

. The

 supplied 

motorised valve must be used in 

accordance with Building 

Regulation  G3. This is wired from 

the supplied cylinder thermostat,

 

wired as high limit stat

.

Please follow lower diagram: 

‘Wiring for Thermistor Controlled 

Heat Pump

’.

 

 

Probe position

Channel 

running 

from 

base of 

cylinder

N L

C NC

NO

N L

C NC

NO

ST6400

Programmer

HW

ON

HTG

ON

ST6400

Programmer

HW

ON

HTG

ON

Using Cylinder Thermostat as 

high limit stat only

 - coil the 

grey temperature probe wire 

inside thermostat box and insert 

black probe into thermostat 

pocket of cylinder then turn dial 

on front to number 5

Heat pump differential controler

Содержание DGC 200

Страница 1: ...in hot water cylinders in accordance with Building Regulation Part L Domestic Heating Compliance Guide This OSO cylinder must be installed by a competent person and be installed in compliance with the...

Страница 2: ...cludes pressure reducing valve line strainer balanced cold water take off for shower or bidet only check and expansion valve Tundish 3 4 x 22mm Elbow Drain Cock Motorised valve Expansion vessel 1 4 Co...

Страница 3: ...Control Thermostat 80345 10 Cold Feed Tube Not supplied see Table 1 11 Hot Water Outlet 3 4 BSP 12 Elbow Drain Cock 250445 13 Discharge Pipe Not supplied 14 Motorised Valve Not Factory Fitted 15 Expan...

Страница 4: ...6 above 3 1 8 Connect 15mm copper tube from the expansion relief valve 4 and also from the T P valve 5 and join together in a Tee as shown on page 3 3 1 9 Fit the tundish 6 to the bottom connection of...

Страница 5: ...ture and pressure relief valve An internal 18 mm hose can be applied to lead the water to a gully sink or similar 5 2 System flushing This will not be necessary under normal circumstances as the line...

Страница 6: ...cylinder thermostat set at 60 C in line with current government guidelines Lowering the temperature will substantially reduce the amount of usable hot water available on a daily basis and could resul...

Страница 7: ...follow upper diagram Wiring for Standard Heat Pump Thermistor controlled Heat Pumps Many popular Heat Pumps now use a thermistor principle A thermistor temperature sensor is supplied with the Heat Pu...

Страница 8: ...e of cylinder 1 2 E 2 3 1 T6360B 3 3 1 4 G O B1 Br G Y N L E N L E N L ST6400 Heat pump Pump 1 2 3 3 2 3 2 2 2 3 1 V4043H Room thermostat Zone Valve DHW supplied Isolated Mains Supply From Fused Spur...

Страница 9: ...harge from the tundish occurs when water is being heated In this situation maintenance must be carried out by competent person and the precharge pressure must be restored to the original value An annu...

Страница 10: ...tions to motorised valve see 3 6 on page 5 and wiring diagrams on page7 and 8 Intermittent water discharge 1 Reduced expansion vessel charge 1 Follow instruction page 9 Intermittent or slow water disc...

Страница 11: ......

Страница 12: ...lve 6 0 Bar 214005 Part no PRE355030 355030 550853 REDC355030 250445 71242 92000 80345 80314 AX18 AX24 Description Expansion Relief Cartridge Expansion relief valve 8 bar Multibloc Temperature pressur...

Страница 13: ...Regulations 3 Failure to install and commission this appliance to the manufacturer s instructions may invalidate the guarantee The above does not affect your statutory rights For full details on the H...

Страница 14: ...rdance with European Council Directive 98 83 EC or revised version at the date of installation and is not fed with water from a private supply Particular Chloride content Max 250 mg l Sulphate content...

Страница 15: ...ISCHARGE TESTED IS PRIMARY ENERGY SOURCE CUT OUT FITTED NORMALLY 2 PORT VALVE WHAT IS THE PRESSURE REDUCING VALVE SETTING IF FITTED WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED NO YES NO YES NO...

Страница 16: ...ENTS SIGNATURE DATE ENGINEER NAME SERVICE 5 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 7 COMPANY NAME TEL No COMMENTS SIGNATURE DATE ENGINEER NAME SERVICE 9 COMPANY NAME TEL No...

Отзывы: