![Oshkosh JLG X1000AJ Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/oshkosh/jlg-x1000aj/jlg-x1000aj_service-and-maintenance-manual_1655724052.webp)
SECTION 3 - CHASSIS & TURNTABLE
3-22
3121784
Here below is listed the rpm setting according to the
movement required and to the speed selected.
NOTE:
Outriggers rpm depends on the machine condition.
NOTE:
Tracks opposite rotation is carry out with lower
speed.
NOTE:
Aerial contemporary movements including jib, bas-
ket leveling or rotation are carry ion at minimum
rpm.
NOTE:
Double pump valve is not activated with move-
ments together.
Temperature Ongoings (Heaters And Fans)
Lithium battery pack discharge and/or recharge, with pos-
itive lithium battery level (SOC>0), is possible over 14°F (-
10°C).
In cold environmental temperature (not lower than -13°F
(-25°C), the on-board electric heaters automatically warm
up the cells, they are activated by the BMS when the mini-
mum cell temperature goes down 32°F (0°C), they are
automatically switched off when the minimum cell tem-
perature raises over the 35.6°F (2°C).
In case of battery charger is connected, till 32°F (0°C) it
supplies only 5A in order to surely feeds only the heaters,
waiting positive temperatures to recharge the cells.
In cold environmental temperature (from -13°F (-25°C) to
32°F (0°C), with null lithium battery level (SOC = 0), the
heaters work only while the cable is plugged to the elec-
tric network (battery charger activated).
While heaters are working on the display will appear the
icon batteries cold, and machine could be moved only in
lower speed (turtle).
In hot environmental temperature, the fans system auto-
matically cool down the cells, they are automatically acti-
vated by the BMS when cells temperature raises over
98.6°F (37°C), they are automatically switched off when
cells temperature goes down the 95°F (35°C).
Diagnostics And Fault Codes
The main devices composing the lithium batteries system
are able to carry out self-diagnosis informing the operator
by the remote control display, in particular they eventually
display informative icons and provide fault codes.
Self-diagnosis is carry out by:
•
BMS (Battery Management System)
•
Battery charger
•
Inverter
Further information about Lithium system, fault codes and
diagnose are detailed by Lithium system specific training.
LITHIUM SYSTEM RPM SETTING
TURTLE
NORMAL/ HARE
MOVEMENT (*)
1500
1500 + double
pump
1st and 2nd booms UP
900
1950
1st and 2nd booms DOWN
900
1950
3rd boom UP
900
1500
3rd boom DOWN
1500
1950 + double
pump
Telescope OUT
1500
1950
Telescope IN
900
1050
Turret rotation
900
900
Basket rotation
900
900
Basket levelling
900
1050
Jib UP
900
900
Jib DOWN
1500
3000
Tracks forward or backward
1500
3000
Tracks opening or closing
3000
3000
Auto stabilization with maximum one
outrigger on the ground
1500
1500
Auto stabilization with two or three out-
riggers on the ground
3000
3000
Auto stabilization with all outrigger on
the ground
3000
3000
Outriggers Auto retraction with all out-
rigger lifted from the ground
1500
1500
Outriggers Auto retraction with at least
one outrigger on the ground
"BATTERY COLD/HEATER ACTIVATED"
ICON
Go to