SECTION 6 - JLG CONTROL SYSTEM
6-28
3121784
Software Recovery By Modem
In case of main machine software in the master board soft-
ware is corrupted or missing, if the modem contains the
main machine software it is able to install the software in
the master board.
When the modem installs the main machine software on
the master board, the first part of the installing process is
the erasing of the eventual software on master board, so
that the remote control display will show wrong images.
While the installing process is in progress the machine
must been left switched on for 10-15 minutes, till the
ground green light comes on flashing.
6.6
CODE MENU
The machine diagnostic system identify faulty as short cir-
cuits and missing connections to the valve coils, further-
more monitoring the circuit load.
For some faulty affecting on aerial part valve coils, which
include the gravity emergency descent valves, the sum-
ming oil pump valve, the functions could be prevented.
To restart the functions have to turn OFF (ground key OFF)
and then ON the machine, as a result all the function are
then active with exception the faulty one.
For some faulty affecting on ground part valve coils, which
include outrigger movements, track widening, the func-
tions could be prevented.
To restart the functions have to turn OFF (ground key OFF)
and then ON the machine, as a result all the function are
then active with exception the faulty one.
In case of the display shows the icon FAIL INPUT OUT, as
shows here below, it means a faulty issue present on the
electric connection.
By the remote control, pressing button 6 - SERVICE and
then keeping pressed button 3 - ERR --> COD, it will be dis-
played the CODE MENU, that is a list of DEVICE with poten-
tially anomalous signal.
GREEN LIGHT
ELECTRIC CONNECTION
ANOMALY IN PROGRESS
Go
to
Discount-Equipment.com
to
order
your
parts