SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-26
– JLG Lift –
3121132
6.8 PROPANE FUEL SYSTEM PRESSURE RELIEF
THE PROPANE FUEL SYSTEM OPERATES AT PRESSURES UP TO 312
PSI (21.5 BAR). TO MINIMIZE THE RISK OF FIRE AND PERSONAL
INJURY, RELIEVE THE PROPANE FUEL SYSTEM PRESSURE (WHERE
APPLICABLE) BEFORE SERVICING THE PROPANE FUEL SYSTEM COM-
PONENTS.
To relieve propane fuel system pressure:
1. Close the manual shut-off valve on the propane fuel tank.
2. Start and run the vehicle until the engine stalls.
3. Turn the ignition switch OFF.
RESIDUAL VAPOR PRESSURE WILL BE PRESENT IN THE FUEL SYS-
TEM. ENSURE THE WORK AREA IS WELL VENTILATED BEFORE DIS-
CONNECTING ANY FUEL LINE.
6.9 PROPANE FUEL SYSTEM LEAK TEST
NEVER USE AN OPEN FLAME OF ANY TYPE TO CHECK FOR PROPANE
FUEL SYSTEM LEAKS.
Always inspect the propane fuel system for leaks after per-
forming service. Check for leaks at the fittings of the serviced
or replaced component. Use a commercially available liquid
leak detector or an electronic leak detector. When using both
methods, use the electronic leak detector first to avoid con-
tamination by the liquid leak detector.
Содержание JLG 3394RT
Страница 21: ...SECTION 1 SAFETY PRECAUTIONS 1 12 JLG Lift 3121132 NOTES...
Страница 51: ...SECTION 3 USER RESPONSIBILITIES AND MACHINE CONTROL 3 20 JLG Lift 3121132 NOTES...
Страница 60: ...SECTION 4 MACHINE OPERATION 3121132 JLG Lift 4 9 SIDESLOPE GRADE LEVEL Figure 4 1 Grade and Sideslope...
Страница 65: ...SECTION 4 MACHINE OPERATION 4 14 JLG Lift 3121132 NOTES...
Страница 97: ...SECTION 7 INSPECTION AND REPAIR LOG 7 2 JLG Lift 3121132 Table 7 1 Inspection and Repair Log Date Comments...
Страница 99: ......
Страница 100: ......