Operating instructions for Pool control-40.net filter control unit
Page: 7 (34)
Connecting the power supply for a 230V pump (with electronic motor protection
enabled)
If a 230V pump is meant to be monitored by the electronic motor protection
device, the option Filter pump - type: 3-phase pump must be selected for the filter
pump. The trip current for the motor protector must be set to the rated current of
the pump (specified on the type plate). For the electronic motor protection to work
correctly, the electrical power to the motor must pass via all three switching
contacts of the filter control unit (place link between terminals L2 and L2 and
between U1 and V1; connect pump to W1).
The factory-inserted link between the two WSK terminals must be removed when
connecting a pump fitted with a thermal winding protection switch (winding
thermostat). If the pump does not have a winding protection switch, the link must
remain screwed in place. These terminals are live and carry a mains voltage!
Connecting the power supply for a Speck ECO-Touch-Pro pump
A Speck ECO-Touch-Pro pump can be connected directly to the
PC-40 unit. Connect the speed controller to terminals 6-14.
A separate mains power supply must be provided for the pump. The
power supply cannot be provided by the PC-40.
There must be a link inserted between the two WSK terminals
(winding protection switch).
The option Filter pump - type: var. speed pump must be selected for
the filter pump in the configuration menu.
Always refer to the operating instructions for the pump.
Connecting the power supply for a Speck ECO-VS pump
A Speck ECO-VS pump can be connected directly to the PC-40 unit.
Connect the speed controller to terminals 6-14.
A separate mains power supply must be provided for the pump. The
power supply cannot be provided by the PC-40.
There must be a link inserted between the two WSK terminals
(winding protection switch).
The option Filter pump - type: var. speed pump must be selected for
the filter pump in the configuration menu.
Always refer to the operating instructions for the pump.
The digital inputs must be set at the pump to "dI" in the pump setup
menu.
Connecting the power supply for a Speck ECO-Motion pump
A Speck ECO-Motion pump can be connected directly to the PC-40
unit. Connect the speed controller to terminals 6-13.
A separate mains power supply must be provided for the pump. The
power supply cannot be provided by the PC-40.
There must be a link inserted between the two WSK terminals
(winding protection switch).
The option Filter pump - type: var. speed pump must be selected for
the filter pump in the configuration menu.
Always refer to the operating instructions for the pump.
In the Setup menu on the pump, the external control must be enabled
for "digital fixed speeds" with the signal type "continuous signal". The
speeds required for ECO mode, normal mode and backwash mode