to delete them. 

1. Press  the 

  key  as  often  as  required  until  the  switching  time  to  be 

deleted is displayed 

10:00
16:00

3.

 

2. The  switching  time  is  deleted  if  you  press  the 

  and 

  keys 

simultaneously. 

 

 

Note: 
If you press the   key, the current time is taken over

.

 

Programming backflushing 

 

 

Use the   key to control backflushing using the bar valve.  

1. Once the   key has been pressed the first time, you can use the   and 

 keys to set the backflushing duration 

  10 Sek.

Rückspül

2. Once the   key has been pressed the next time, you can use the   and 

 keys to set the rinsing duration 

  10 Sek.

Klarspül

3. Once the   key has been pressed again, you can set the time of the 

rinsing process 

Mo  16:00

1. Start

.  

In the first stage, the   and   keys are used to set the minutes. 
If you press the   key, the current time is taken over. 

4. Press the   key again 

 the hours in the switch-on time blink 

You can now use the   and   keys to set the hours. 

5. Press the   key again 

 the switch-on time weekday blinks. 

You can now use the   and   keys to set the weekday. 

6. Further start times can be programmed in the same manner as 

described in points 1 to 5.  

Deleting switching times: 

If you press the   and   keys simultaneously, the rinsing time shown in the 
display will be deleted. 

 

 

Note: 
If you press the 

 

key, the current time is taken over

.

 

 

Start backflushing process manually 

If the backflushing key   is pressed for 3 seconds without interruption, the 
backflushing  process  will  start.  Backflushing  will  not  start  unless  a 
backflushing duration has been entered. 

Info key 

 

If you press the INFO key, the program version number will be displayed 

  

If the info key is pressed several times successively, the following information 
can be called up. 

1)  Language 

  PC250

ver.1.xx

Содержание POOL-Control-250

Страница 1: ...pecifications Dimensions 220mm x 220mm x 100mm Operational voltage 400V 50Hz Control system power consumption ca 10VA Switching capacity Pump max 3 0 kW AC3 Heater max 2A Dosing system max 8A Protecti...

Страница 2: ...ng switching times 8 Start backflushing process manually 8 Info key 8 Installation 9 Electrical power supply 9 Mains connection when using 400V 3 phase pump 10 Mains connection when using 230 V AC pum...

Страница 3: ...n on time 17 Heater priority circuit 18 Solar heater priority circuit 18 Frost protection 19 Pump time 19 heater time 19 Solar time 19 Motor defect 19 Phase fields 19 Int backflushing intern 19 Ext Ba...

Страница 4: ...y This controller is not usable for other types of solar collector Terminals for electronic level regulation NR 12 TRS 2 Art No 3030075020 enable convenient automatic regulation of the swimming pool w...

Страница 5: ...R ck sp len The filter pump is switched on because backflushing is taking place using the bar valve connected Klar sp len The filter pump is switched on because rinsing is taking place using the bar v...

Страница 6: ...he control system this indicator lamp is used to show the current operating status of the solar heater Backflushing process indicator lamp This indicator lamp always illuminates if backflushing or rin...

Страница 7: ...y shows 0 00 0 00 1 the minute display of the top time switch on time blinks Note if you press the key the current time will be taken over 3 You can now use the and keys to set the required switch on...

Страница 8: ...et the minutes If you press the key the current time is taken over 4 Press the key again the hours in the switch on time blink You can now use the and keys to set the hours 5 Press the key again the s...

Страница 9: ...display automatically Installation The controller must be protected against moisture in accordance with its protection class and the fixed to a plain fireproof support with suitable loading capacity...

Страница 10: ...L1 N WSK schutz 230V max 8A Filterpumpe max B16A Vorsicherung FI Schalter Netz 1 N 230V 50Hz 25A 0 03A N kontakt The bridge fitted in the works between the terminals labelled WSK must be removed if a...

Страница 11: ...N A 230 V bar valve for rinsing can be connected to terminals U4 and N Both valves will be controlled by the internal backflushing controller Heater and dosing systems are blocked during the backflus...

Страница 12: ...h good heat transfer between temperature sensor and swimming pool water an immersed sleeve R Art No 3200200003 should be built into the piping system The sensor polarity is as required A solar tempera...

Страница 13: ...e right Fuses The electronic control system is protected by a 0 25A fine wire fuse on the PCB in the inside of the device The short circuit protection for the filter pump must be provided by a backup...

Страница 14: ...tched off temporarily by the EUROTRONIK 10 or the NR 12 TRS 2 level regulation system Backflushing The filter pump is switched on because backflushing is taking place using the bar valve Rinsing The f...

Страница 15: ...defective Caution If both temperature sensors are at the same temperature the solar sensor must never display a higher value than the water temperature sensor otherwise the solar heater will not swit...

Страница 16: ...e value is 0 the largest 15 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The adjusted value will be saved automatically A temperature diff...

Страница 17: ...d the filter unit is switched off and the display shows the following Min Solar s Minimale Einschaltzeit der Solarheizung 120 2 Use the and keys to change the minimum time in stages of 10s The smalles...

Страница 18: ...3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The additional heater priority is switched off at the works Solar heater priority circuit Thi...

Страница 19: ...ump time This line displays the total operating hours for the filter pump heater time This line displays the total operating hours for the additional heater Solar time This line displays the total ope...

Страница 20: ...he filter pump operating status is displayed in the top line of the service terminal the pump can be switched on or off manually 1 Once the key has been pressed the filter unit is switched off and the...

Страница 21: ...tinues to operate Dosing unit When the dosing unit operating status is displayed in the top line of the service terminal it can be switched on or off manually 1 Once the key has been pressed the filte...

Страница 22: ...ormal diagnosis display appears and the filter unit continues to operate Diagnosis This menu is only accessible for trained osf service technicians Language When the language is shown in the top line...

Страница 23: ...ungsschutz Filterpumpe Temperaturf hler Heizungspumpe W Netz 400V Dosiertechnik Dosier pumpe N Netz 230V 1 N PE Ausgang Pumpe Druckschalter Netz 230V 1 N PE Stellantrieb Ge ffnet bei R cksp len und Kl...

Страница 24: ...PC 250 Filter control unit operating manual Page 24 24...

Отзывы: