Front panel displays and controls:
solar button ON/OFF
adjust temperature
adjust switching times
control light filter pump
select operating mode
control lights operating mode
art
set time
adjust backflushing
control light solar heating
control light heating
heating ON/OFF
LCD
adjustment buttons
info Button
control light backflushing
LCD display
LCD display
23,4
14:46
°C
Normal operating display with current water temperature and time.
Auffang-
behälter
The filter pump is switched on by the NR-12-TRS-2 level regulation system.
6-Wege
Spülung
The filter pump is switched on by the EUROTRONIK-10 backflushing
control system.
Pumpe
gesperrt
The filter pump is switched off by the EUROTRONIK-10 or the NR-12-TRS-
2 level regulation system.
Rück-
spülen
The filter pump is switched on because backflushing is taking place using
the bar valve connected.
Klar-
spülen
The filter pump is switched on because rinsing is taking place using the bar
valve connected.
Motor-
schutz
The filter pump has been switched off by the electronic motor protection
system. Once the pump has cooled down and the cause of overloading has
been rectified, it can be switched on again using the key.
Phase
fehlt
The filter pump is switched off because current is not flowing in all 3 phases
of the 3-phase current network. It can be switched on again using the key
once the error has been rectified.
Selecting operating mode
The control system can be switched off or you can select between manual
and automatic operating mode using the
key.
Caution!
This does not
mean that the control system has been switched to voltage-free! The
operating mode selected is displayed using the indicator lamps next to the
key.